A Biomechanical Comparison of Three Miniature Locking Plate Systems in a Rabbit Radial and Ulnar Fracture Model
Harue Takizawa1, Muneki Honnami2, Takamasa Sakai3
1Department of Veterinary Medical Science, Laboratory of Veterinary Emergency Medicine, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Bunkyo-ku, Tokyo, Japan.
Objective:
The aim of this study was to evaluate the biomechanical properties of three different miniature locking plate systems used to fixate radial and ulnar fractures in toy breed dogs. Implant size, shape, material and locking systems differ, and their influence on the fracture healing process is unknown. In the present study, we aimed to investigate this matter in vivo using rabbit radial and ulnar fracture models.
Study Design:
Eighteen rabbits were randomly divided into three groups, and the left radius and ulna were osteotomized to create fracture models. The osteotomies were then fixated using either the TITAN LOCK 1.5, Fixin micro or LCP 1.5 system. Radiographs were obtained 2, 3 and 4 weeks after surgery. Four weeks after surgery, the radiuses were collected and used for biomechanical testing or histological examinations.
Results:
During the 4 weeks of observation, no adverse effects due to the implants occurred. The radiographic scores in each group did not differ significantly at any time point. The maximum load in the LCP group was significantly higher than that in the TITAN and Fixin groups. There was no significant difference in bending stiffness or work to failure among the groups. Initial fracture healing via woven bone was evident at histological evaluation.
Conclusions:
All three miniature locking plate systems provided adequate fracture stabilization 4 weeks after surgery, despite their differences, in rabbit models.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation