Related Experiment Video
Updated: Jan 22, 2026

Use of the Protease Fluorescent Detection Kit to Determine Protease Activity
Published on: August 4, 2009
Application of Sample6 DETECT™ HT/L Kit for the Detection of Listeria in Mixed Leafy Greens
Elba Veronica Arias-Rios1, Kristina Tenney2, Tam Mai1
1Molecular Epidemiology, Inc., 15300 Bothell Way NE, Lake Forest Park, WA 98155.
Background:
Early and accurate detection of Listeria in foods is vital. Current methods require 24 h enrichment for detection.
Objective:
This study aimed to demonstrate enhanced early detection of Listeria in mixed leafy greens using Sample6 DETECT™ HT/L, a phage-based detection system.
Methods:
A method comparison between the reference method (U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 10) for the detection of Listeria spp. and the Sample6 DETECT HT/L using a new proprietary R2 Medium was performed in mixed leafy greens.
Results:
Using the R2 Medium enrichment with Sample6 DETECT HT/L, detection of L. innocua was possible at 12 h (with a centrifugation step), and L. monocytogenes was detected by 18 h, with equivalent performance as the 24 h enrichments using the reference method detection. The Sample6 DETECT HT/L gave an equivalent performance for L. innocua at 15 h as the reference method at 24 h. Detection was accomplished by the addition of reagents in the kit, following the package insert, and reading results in a detection chamber using a 96-well plate reader that detects a fluorescent signal.
Conclusions:
Results indicate the new R2 Medium and Sample6 DETECT HT/L allowed for earlier detection of Listeria spp. in mixed leafy greens.
Highlights:
Sample6 DETECT HT/L with the new R2 Medium allowed the early detection of Listeria spp. and may be applied in other food matrices and environmental samples.
More Related Videos
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Green Algae
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

