Percutaneous arthroscopic calcaneal osteosynthesis for displaced intra-articular calcaneal fractures: Systematic review and surgical technique
Related Experiment Video
Updated: Jan 22, 2026

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
Stanislas Marouby1, Nicolas Cellier1, Olivier Mares1
1Department of Orthopedic Surgery, Caremeau University Hospital, place du Professeur Robert Debré, 30029 Nimes, France.
Background:
The aim of this study was to systematically evaluate the available literature on technique and outcomes of percutaneous arthroscopic calcaneal osteosynthesis for displaced intra-articular calcaneal fractures.
Methods:
A systematic review of the literature available in MEDLINE, EMBASE, and the Cochrane Library database was performed, including studies from January 1985 to august 2018. The literature search, data extraction, and quality assessment were conducted by 2 independent reviewers. The surgical technique and perioperative management, clinical outcomes scores, radiographic outcomes and complication rate were evaluated.
Results:
Of 66 reviewed articles, 8 studies met the inclusion criteria. The included studies reported on the results of 152 patients. At last follow up the mean American Orthopaedic Foot & Ankle Society ankle-hindfoot was ranging from 72.1 to 94.1. The complication rate was low, including only one superficial infection.
Conclusions:
The studies included were of too little level of evidence to allow for data pooling or meta-analysis. However, the percutaneous arthroscopic calcaneal osteosynthesis seems to be a good option for displaced intra-articular calcaneal fractures with a low complication rate. Appropriately powered randomized controlled trials with long-term follow up are needed to confirm the efficacy of this technique.
Level Of Evidence:
Level III, systematic review of Level III studies.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
06:41A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Related Concept Videos
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Position and Displacement
Displacement Current
Position and Displacement Vectors
Further, several important kinds of...
Significance of Displacement Current