Accuracy and inter-rater reliability of lung auscultation by bovine practitioners when compared with ultrasonographic findings
Related Experiment Video
Updated: Jan 22, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Bart Pardon1, Sébastien Buczinski2, Piet R Deprez1
1Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
Abstract:
In practice, veterinary surgeons frequently rely on lung auscultation as a confirmation test for pneumonia. To what extent diagnostic accuracy of lung auscultation varies between different practitioners is currently unknown. In this diagnostic test study, 49 Dutch veterinarians each auscultated between 8 and 10 calves, and communicated whether they would decide to treat the animal with antimicrobials or not. They were not allowed to perform any other aspect of the clinical examination. Their decisions were compared with lung ultrasonography findings. The average sensitivity and specificity of lung auscultation were 0.63 (sd=0.2; range=0.2-1.0) and 0.46 (sd=0.3; range=0.0-1.0), respectively. Of the participants, 8.2 per cent were 100 per cent sensitive, 16.3 per cent were 100 per cent specific, and only 4.0 per cent were perfect. The Krippendorff's alpha was 0.18 (95 per cent confidence interval: -0.01 to 0.38), signifying poor reliability between multiple raters. Regardless of the poor diagnostic accuracy in this study, especially the large variation in a confirmation test between different practitioners could potentially cause professional damage as well as misuse of antimicrobials. This study could be seen as a gentle stimulus to regularly evaluate one's diagnostic skills. Both complementary training and the use of more accurate techniques with less inter-rater variation could improve the situation.
Related Concept Videos
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Reliability and Validity
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.

