Related Experiment Video
Updated: Jan 22, 2026

Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Novel mesh-derived right ventricular free wall longitudinal strain analysis by intraoperative three-dimensional
Marius Keller1, Tobias Lang2, Andreas Schilling2
1Department of Anaesthesiology and Intensive Care Medicine, University Hospital Tuebingen, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tuebingen, Germany. marius.keller@med.uni-tuebingen.de.
Abstract:
Longitudinal right ventricular (RV) function is substantial and might be reflected by free wall longitudinal strain (FWLS). Software solutions for FWLS analysis by two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) are available, but data on validation are sparse. In this study, a novel method for FWLS analysis on 3D meshes ("mesh surface", MS-FWLS,) was tested for feasibility and compared to available parameters. 80 patients undergoing left-sided cardiac valve surgery with intraoperative TEE were included retrospectively. 2D-FWLS, 3D-derived (3Dd)-FWLS (assessed in optimized four-chamber views after volume analysis) and MS-FWLS were measured and compared to conventional parameters (3Dd-TAPSE, FAC and RVEF). The mean FWLS values did not differ significantly between methods (- 19.0 ± 6.1%, - 20.0 ± 7.3%, - 19.5 ± 7.3% for 2D-, 3Dd- and MS-FWLS, respectively). No significant differences in the mean FWLS between patients with normal or increased pulmonary artery pressures as well as normal or reduced left ventricular ejection fraction were observed. Agreement was best between 3Dd- and MS-FWLS (r = 0.89, bias = - 1.0%, LOA ± 6.9%). Conventional echocardiographic parameters yielded poorer intermodality agreement. In patients with discrepant results between 2D- and 3Dd-FWLS, 3Dd-FWLS and MS-FWLS yielded similar results (r = 0.82, bias = - 0.3%, LOA ± 8.6%), while 2D-FWLS and MS-FWLS did not. Intra- and interobserver variabilities of strain analyses were low. MS-FWLS might represent a promising method to overcome artefacts associated with 2D analysis. Its prognostic relevance needs to be investigated in prospective studies.
Related Concept Videos
Three-Dimensional Analysis of Strain
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Longitudinal Research
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...