Transient elastography: should XL probe be used in all overweight patients?
Cátia Arieira1,2,3, Sara Monteiro1,2,3, Sofia Xavier1,2,3
1Gastroenterology Department, Hospital da Senhora da Oliveira , Guimarães , Portugal.
Abstract:
Background: Obesity is one of the main factors of transient elastography (TE) failure, considering body mass index (BMI) ≥28 kg/m2 as a limiting factor. The XL probe was designed to overcome this limitation. Aim: To compare the feasibility of the M and XL probes in patients with BMI ≥ 28 kg/m2, to evaluate differences in mean values of controlled attenuation parameter (CAP) and liver stiffness measurement (LSM) between the two probes and find predictive factors of TE failure. Material and methods: Prospective study, including all patients with BMI ≥ 28 kg/m2 consecutively admitted for TE. Results: Included 161 patients. Measurements with M probe were reliable in 69.6% of the patients, with 68.2% of valid measurements in obese population and 58.9% in patients with skin-capsule distance (SCD) >25 mm. In 40 patients (81.6%) with an invalid M probe measurement, a reliable result was obtained with XL probe. We found that SCD >25 mm was the only predictor of M probe failure (OR: 4.9, CI: 1.64-14.63, p = .004). In those patients in which TE was possible with both probes (n = 112), mean CAP was 304 ± 49 dB/m2 with M probe and 301 ± 50 dB/m2 with XL probe (p = .59). Regarding liver stiffness, a mean value of 7.58 ± 3.47 kpas was obtained with the M probe and 6.21 ± 3.44 kpas with the XL probe (p < .001). Conclusion: There is a reliable applicability of the M probe in a high number (68.2%) of patients with a BMI ≥30 kg/m2. A SCD >25 mm was the only predictive factor of M probe failure. Mean values of LSM with XL probe were lower than those obtained with M probe.
More Related Videos
06:53DNA Tension Probes to Map the Transient Piconewton Receptor Forces by Immune Cells
Published on: March 20, 2021
04:51Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
Published on: March 1, 2024
Related Concept Videos
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Patient-centered Care
Drug Dosing: Obese Patients
Drug Dosing: Geriatric Patients