Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Age and sex estimation based on pulp cavity volume using cone beam computed tomography: development and validation of
Vanessa M Andrade1,2, Rocharles C Fontenele3, Andreia Cb de Souza1,4
1Forensic Odontology Service, Afrânio Peixoto Legal Medicine Institute, Rio de Janeiro, Brazil.
Objectives:
To develop and validate formulas for age and sex estimation based on the pulp cavity volume of teeth using cone beam CT.
Methods:
The sample was composed of 116 cone beam CT scans from Brazilian individuals of both sexes, ranging in age from 13 to 70 years. A total of 232 teeth (upper central incisors and canines) were evaluated. Two calibrated examiners determined pulp cavity volumes using the ITK-SNAP software. Pearson's correlation test was used to assess the correlation between chronological age and pulp volume. Linear and logistic regression models were developed for age and sex estimation, respectively, and were validated in another sample of 72 teeth.
Results:
Pearson's correlation coefficients between age and pulp volume were negative and significant (p < 0.0001) for both teeth (r = -0.8782 for central incisors and r = -0.8738 for canines). The age estimation formulas showed good determination coefficients (adjusted R² = 0.7614 to 0.8367). For sex estimation, when the age was known, the coefficients were also good (adjusted R² = 0.649 to 0.812). However, when the age was unknown, the coefficients of the sex estimation formulas were low (adjusted R² = 0.047 to 0.393). Validation showed high accuracy of age estimation in individuals older than 35 years, as well as high accuracy of sex estimation when the age was known.
Conclusions:
Our formulas provided excellent results and can be applied to the Brazilian population. The best results were observed for age estimation in females and for sex estimation when the age was known.
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Chemical Formulas
Experimental Determination of Chemical Formula
Formula Mass and Mole Concepts of Compounds
Imaging Studies III: Computed Tomography
Ionic Compounds: Formulas and Nomenclature