Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year
Yu Hwa Pan1,2,3,4, His Kuei Lin1,5, Jerry C-Y Lin1,6
1School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 10692, Taiwan.
Objective:
To describe remodeling of the mesial and distal marginal bone level around platform-switched (PS) and platform-matched (PM) dental implants that were sandblasted with large grit and etched with acid over a three-year period.
Materials And Methods:
Digital periapical radiographs were obtained at the following time-points: during Stage I of the surgical placement of dental implants, before loading, immediately after loading (baseline), and one, three, six, 12, and 36 months after loading for measuring the horizontal and vertical marginal bone levels.
Results:
Sixty implants were successfully osseointegrated during the overall observation period. Vertical marginal bone levels for the PS and PM dental implants were 0.78 ± 0.77 and 0.98 ± 0.81 mm, respectively, whereas the horizontal marginal bone levels for the PS and PM implants were 0.84 ± 0.45 and 0.98 ± 0.68 mm, respectively. During the time leading up to the procedure until 36 months after the procedure, the average vertical marginal bone level resulted in less bone loss for the PS and PM groups-0.96 ± 1.28 and 0.30 ± 1.15 mm, respectively (p < 0.05). The mean levels of the horizontal marginal bone also showed increases of 0.48 ± 1.01 mm in the PS and 0.37 ± 0.77 mm in the PM groups from the time before loading until 36 months after the procedure. However, these increases were not statistically significant (p > 0.05).
Conclusion:
PS dental implants appeared to be more effective than PM implants for minimizing the mean marginal vertical and horizontal marginal bone loss during the three-year period. Regardless of which abutment connection was used, the dental implant in the present retrospective investigation exhibited minimal marginal bone remodeling, thus indicating long-term stability.
Related Concept Videos
Switching of BJT
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
High-Level and Low-Level Awareness
Leveling Effect
Levels of Organization
Molecules Are Composed of Atoms, and Biomolecules Are Assembled from Molecules:
The most basic levels include atoms, molecules, and biomolecules. Atoms, the smallest unit of ordinary matter, are composed of a nucleus and electrons. Molecules...
Fermi Level
At absolute zero temperature, electrons fill all energy states up to the Fermi level, leaving upper states empty. As the temperature rises,...
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3