Related Experiment Video
Updated: Jan 22, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Hybrid Solid-Phase Extraction for Selective Determination of Methamphetamine and Amphetamine in Dyed Hair by Using
Nam Hee Kwon1, Yu Rim Lee1, Hee Seung Kim1
1Forensic Genetics & Chemistry Division, Supreme Prosecutors' Office, Seoul 06590, Korea.
Abstract:
Sample preparation is an important step in the isolation of target compounds from complex matrices to perform their reliable and accurate analysis. Hair samples are commonly pulverized or processed as fine cut, depending on preference, before extraction by techniques such as solid-phase extraction (SPE), liquid-liquid extraction, and other methods. In this study, a method based on hybrid solid-phase extraction (hybridSPE) and gas chromatography-mass spectrometry (GC-MS) was developed and validated for the determination of methamphetamine (MA) and amphetamine (AP) in hair. The hair samples were mechanically pulverized after washing with de-ionized water and acetone. The samples were then sonicated in methanol at 50 °C for 1 h and centrifuged at 50,000× g for 3 min. The supernatants were transferred onto the hybridSPE cartridge and extracted using 1 mL of 0.05 M methanolic hydrogen chloride. The combined solutions were evaporated to dryness, derivatized using pentafluoropropionic anhydride, and analyzed by GC-MS. Excellent linearity (R2 > 0.9998) was achieved in the ranges of 0.05-5.0 ng/mg for AP and 0.1-10.0 ng/mg for MA. The recovery was 83.4-96.8%. The intra- and inter-day accuracies were -9.4% to 5.5% and -5.1% to 3.1%, while the intra- and inter-day precisions were within 8.3% and 6.7%, respectively. The limits of detections were 0.016 ng/mg for AP and 0.031 ng/mg for MA. The validated hybridSPE method was applied to dyed hair for MA and AP extraction and compared to a methanol extraction method currently being used in our laboratory. The results showed that an additional hybridSPE step improved the recovery by 5.7% for low-concentration quality control (QC) samples and by 24.1% for high-concentration QC samples. Additionally, the hybridSPE method was compared to polymeric reversed-phase SPE methods, and the absolute recoveries for hybridSPE were 50% and 20% greater for AP (1.5 ng/mg) and MA (3.0 ng/mg), respectively. In short, the hybridSPE technique was shown to minimize the matrix effects, improving GC-MS analysis of hair. Based on the results, the proposed method proved to be effective for the selective determination of MA and AP in hair samples.
More Related Videos
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles