Related Experiment Video
Updated: Jan 22, 2026

An R-Based Landscape Validation of a Competing Risk Model
Published on: September 16, 2022
Validation of the Systematic COronary Risk Evaluation - Older Persons (SCORE-OP) in the EPIC-Norfolk prospective
Lotte Verweij1, Ron J G Peters2, Wilma J M Scholte Op Reimer3
1ACHIEVE Centre of Applied Research, Amsterdam University of Applied Sciences, Amsterdam, the Netherlands.
Background:
The Systematic COronary Risk Evaluation - Older Persons (SCORE-OP) algorithm is developed to assess 10-year risk of death due to cardiovascular disease (CVD) in individuals aged ≥65 years. We studied the performance of SCORE-OP in the European Prospective Investigation of Cancer Norfolk (EPIC-Norfolk) prospective population cohort.
Methods:
10-year CVD mortality as predicted by SCORE-OP was compared with observed CVD mortality among individuals in the EPIC-Norfolk cohort. Persons aged 65-79 years without known CVD were included in the analysis. CVD mortality was defined as death due to ischemic heart disease, cardiac failure, cerebrovascular disease, peripheral-artery disease or aortic aneurysm. Predicted 10-year CVD mortality was calculated by the SCORE-OP algorithm, and compared to observed mortality rates. The area under the receiver operator characteristics curve (AUROC) was calculated to evaluate discriminative power. Calibration was evaluated by calculating ratios of predicted vs observed mortality and by Hosmer-Lemeshow tests.
Results:
A total of 6590 individuals (45.8% men), mean age 70.2 years (standard deviation 3.3) were included. The predicted mortality by SCORE-OP was 9.84% (95% confidence interval (CI) 9.76-9.92) and observed mortality was 10.2% (95% CI 9.52-11.04), ratio 0.96. AUROC was 0.63 (95% CI 0.60-0.65), and X2 was 3.3 (p = 0.92).
Conclusion:
SCORE-OP overall accurately estimates the rate of CVD mortality in a general population aged 65-79 years. However, while calibration is excellent, the discriminative power of the SCORE-OP is limited, and as such cannot be readily implemented in clinical practice for this population.
More Related Videos
Related Concept Videos
Reliability and Validity
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Second-order Op Amp Circuits
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
Conservation of Small Populations
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
What is Population Genetics?

