Lead extraction for cardiac implantable electronic device infection: comparable complication rates with or without
Frank Bracke1, Niels Verberkmoes1, Marcel van 't Veer1
1Department of Cardiology and Cardiopulmonary Surgery, Catharina Hospital, Michelangelolaan 2, Eindhoven, Netherlands.
Aims:
Abandoned leads are often linked to complications during lead extraction, prompting pre-emptive extraction if leads become non-functional. We examined their influence on complications when extracted for device-related infection.
Methods And Results:
All patients undergoing lead extraction for device-related infection from 2006 to 2017 in our hospital were included. The primary endpoint was major complications. Out of 500 patients, 141 had abandoned leads, of whom 75% had only one abandoned lead. Median cumulative implant times were 24.2 (interquartile range 15.6-38.2) and 11.6 (5.6-17.4), respectively years with or without abandoned leads. All leads were extracted only with a femoral approach in 50.4% of patients. Mechanical rotational tools were introduced in 2014 and used in 22.2% of cases and replacing laser sheaths that were used in 5% of patients. Major complications occurred in 0.7% of patients with abandoned leads compared with 1.7% of patients with only active leads (P = 0.679). Failure to completely remove all leads was 14.9% and 6.4%, respectively with or without abandoned leads (P = 0.003), and clinical failure was 6.4% and 2.2% (P = 0.028), respectively. Procedural failure dropped to 9.2% and 5.7% (P = 0.37), respectively after the introduction of mechanical rotational tools. The only independent predictor of procedural and clinical failure in multivariate analysis was the cumulative implant duration.
Conclusion:
Despite longer implant times, patients with abandoned leads did not have more major complications during lead extraction. Therefore, preventive extraction of non-functional leads to avoid complications at a later stage is not warranted.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Electron Affinity
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...