Related Experiment Video
Updated: Jan 21, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Effect of layering gingiva-shade composite resin on the strength of denture base polymers
Edmond Armand Bedrossian1, Kwok-Hung Chung2, Van Ramos3
1Graduate student, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Private practice, San Francisco, Calif.
Statement Of Problem:
Acrylic resin denture base materials, fabricated with either a traditional technique or computer-aided design and computer-aided manufacturing (CAD-CAM) technique, layered with different thicknesses of gingiva-shade composite resin may affect the strength of the definitive prostheses and have not been investigated.
Purpose:
The purpose of this in vitro study was to assess the flexural strength of acrylic resin denture base materials modified by layering different thicknesses of gingiva-shade composite resin.
Material And Methods:
Two denture acrylic resins, heat-polymerized type (Lucitone 199) and CAD-CAM prepolymerized type (AvaDent) polymethyl methacrylate (PMMA) resin, were used as the base materials. Three-millimeter-thick specimens were fabricated and prepared according to the ISO 1567 and ISO 20795-1:2013 and were used as the controls. A proprietary gingiva-shade composite resin (GRADIA gum shades) was used to replace different thicknesses (0.5 mm, 1.0 mm, and 1.5 mm) of the denture base materials, giving 4 groups for each tested material (n=16). A 3-point loading test was conducted by using a universal testing machine and a custom fixture with a crosshead speed of 5 mm/min. The maximum fracture loads were recorded, and ultimate flexural strength values were calculated. The collected data were statistically analyzed with ANOVA and the Tukey honestly significant difference (HSD) tests (α=.05). Representative fractured specimens were examined under a stereomicroscope at ×20 magnification and a scanning electron microscope to determine the interface and fracture patterns.
Results:
The mean ±standard deviation of ultimate flexural strengths for the heat-polymerized acrylic resin specimens ranged from 94.79 ±9.89 MPa to 40.34 ±12.79 MPa, and that of the CAD-CAM prepolymerized acrylic resin ranged from 125.98 ±7.96 MPa to 64.16 ±20.77 MPa. Acrylic resin denture base materials after layering with gingiva-shade composite resin had a significantly lower mean fracture load than the controls (P<.05). The Tukey HSD test revealed that the control groups had significantly higher flexural strength values compared with the other tested specimens within each denture acrylic resin group layered with gingiva-shade composite resin (P<.05). The SEM images displayed brittle fracture exhibiting well-defined, flat, compact, and organized surface fractures.
Conclusions:
The flexural strengths of CAD-CAM prepolymerized acrylic resins were higher than those of the heat-polymerized denture acrylic resins. The flexural strengths of all 3 thicknesses of the CAD-CAM prepolymerized acrylic resins were greater than 65 MPa.
More Related Videos
06:26Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
Published on: October 6, 2017
09:06The Effect of Construction and Demolition Waste Plastic Fractions on Wood-Polymer Composite Properties
Published on: June 7, 2020
Related Concept Videos
Relative Strengths of Conjugate Acid-Base Pairs
Acid and Bases: Ka, pKa, and Relative Strengths
Polymers
Acid/Base Strengths and Dissociation Constants
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...