Related Experiment Video
Updated: Aug 16, 2026

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
Electrocardiogram interpretation in NCAA athletes: Comparison of the 'Seattle' and 'International' criteria
Nicola Hyde1, Jordan M Prutkin2, Jonathan A Drezner1
1Department of Family Medicine, Sports Medicine Section, University of Washington, United States of America.
Background:
Accurate electrocardiogram (ECG) interpretation in competitive athletes requires the distinction of physiological adaptations from findings suggestive of a pathological condition. The purpose of this study was to compare the performance of the Seattle Criteria to the International Criteria in a large dataset of NCAA athletes screened with an ECG.
Methods:
ECGs from 5258 NCAA athletes who underwent prior ECG screening were re-examined by two experts in the field of sports cardiology and by ECG interpretation software by Cardea (© 2018 Cardiac Insight Inc.) using the Seattle and International Criteria. Each ECG was classified as normal or abnormal and the specific ECG abnormalities noted. Chi-squared analysis was used for statistical comparisons.
Results:
The total number of ECGs flagged as abnormal by expert over-read decreased from 158 (3.0%) using the Seattle Criteria to 83 (1.6%) using the International Criteria (p<0.0001). Likewise, the total number of abnormal ECGs using ECG interpretation software by Cardea decreased from 278 (5.3%) using Seattle Criteria programming compared to 134 (2.5%) using International Criteria programming (p<0.0001). The most common ECG abnormality by expert over-read using the International Criteria was T wave inversion 40 (48%). The newer definition of pathological Q waves reduced the number of ECGs flagged as abnormal from pathologic Q waves from 69 (Seattle) to 11 (International) (84% reduction; p<0.0001). Expert over-read using both criteria and both Cardea interpretation programs identified all 13 athletes with cardiac pathology associated with sudden cardiac death. Cardea software using the International Criteria had a higher false-positive rate (2.3%) than expert over-read (1.3%) (p=0.0001).
Conclusions:
Use of the International Criteria for ECG interpretation significantly reduces the total abnormal and false-positive ECG rates compared to the Seattle Criteria without compromising sensitivity. Cardea interpretation software performs well and may be a useful tool to assist clinicians.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias