Related Experiment Video
Updated: Jan 21, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
The impact of aortic valve replacement on survival in patients with normal flow low gradient severe aortic stenosis:
Sahrai Saeed1,2,3, Anastasia Vamvakidou1,2, Reinhard Seifert3
1Department of Echocardiography, Royal Brompton Hospital, London, UK.
Aims:
To assess the survival benefit of aortic valve replacement (AVR) in patients with normal flow low gradient severe aortic stenosis (AS).
Methods And Results:
A retrospective study of prospectively collected data of 276 patients (mean age 75 ± 15 years, 51% male) with normal transaortic flow [flow rate (FR) ≥200 mL/s or stroke volume index (SVi) ≥35 mL/m2] and severe AS (aortic valve area <1.0 cm2). The outcome measure was all-cause mortality. Of the 276 patients, 151 (55%) were medically treated, while 125 (45%) underwent an AVR. Over a mean follow-up of 3.2 ± 1.8 years (range 0-6.9 years), a total of 96 (34.8%) deaths occurred: 17 (13.6%) in AVR group vs. 79 (52.3%) in those medically treated, when transaortic flow was defined by FR (P < 0.001). When transaortic flow was defined by SVi, a total of 79 (31.3%) deaths occurred: 18 (15.1%) in AVR group vs. 61 (45.9%) in medically treated (P < 0.001). In a propensity-matched multivariable Cox regression analysis adjusting for age, gender, body surface area, smoking, hypertension, diabetes mellitus, atrial fibrillation, peripheral vascular disease, chronic kidney disease, left ventricular ejection fraction, left ventricular mass, and mean aortic gradient, not having AVR was associated with a 6.3-fold higher hazard ratio (HR) of all-cause mortality [HR 6.28, 95% confidence interval (CI) 3.34-13.16; P < 0.001] when flow was defined by FR. In the SVi-guided model, it was 3.83-fold (HR 3.83, 95% CI 2.30-6.37; P < 0.001).
Conclusion:
In patients with normal flow low gradient severe AS, AVR was associated with a significantly improved survival compared with those who received standard medical treatment.
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Bernoulli's Equation for Flow Normal to a Streamline
The pressure difference depends on the fluid's velocity and radius of curvature. The pressure variation is minimal in flows with nearly straight streamlines. However, the...