Related Experiment Video For Breast Imaging Reporting and Data System (BI-RADS)
Updated: Jan 21, 2026

A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
BI-RADS 4 breast lesions: could multi-mode ultrasound be helpful for their diagnosis?
Gang Liu1, Meng-Ke Zhang2, Yan He2
1Department of Radiology, Chinese People's Liberation Army General Hospital, Beijing 100853, China.
Background:
The malignant probability of Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions is 3-94%, which is a very large span, and thus leads to a high rate of unnecessary biopsy. Therefore, the differential diagnosis of benign and malignant BI-RADS 4 breast lesions has become extremely important. Thus, in this paper, we investigated the diagnostic value of conventional ultrasonography (US), contrast-enhanced ultrasound (CEUS) and shear wave elastography (SWE) for BI-RADS 4 breast lesions, and tried to figure out a multi-mode ultrasonic method for them.
Methods:
From March 2016 to May 2017, 118 breast lesions that were categorized as BI-RADS 4 lesions by US were studied with CEUS and SWE. All the lesions were confirmed by pathology via surgery or vacuum-assisted biopsy. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US, CEUS and SWE were analyzed. Then the diagnostic efficacies of US, CEUS, SWE and the combination of these modalities were compared. Logistic regression analysis was performed to identify the independent risk factors. A multi-mode method to evaluate BI-RADS 4 lesions based on the logistic regression was developed.
Results:
Of the 118 BI-RADS 4 lesions, 74 lesions (62.7%) were benign and 44 lesions (37.3%) were malignant. The diagnostic sensitivity and specificity for US, US + CEUS, US + SWE, US + CEUS + SWE were 88.6% and 75.7%, 86.4% and 94.6%, 88.6% and 90.5%, 97.7% and 93.2%, respectively. The area under the ROC curve (AUC) of US + SWE + CEUS was significantly higher than that of US (P<0.0001), US + CEUS (P=0.020), but there was no significant difference between the AUC of US + SWE + CEUS and the AUC of US + SWE.
Conclusions:
US + CEUS + SWE and US + SWE could significantly improve the diagnostic efficiency and accuracy of US in the diagnosis of BI-RADS 4 breast lesions.
More Related Videos
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound
Published on: August 14, 2012
05:50International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
Modes of Standing Waves - I