Related Experiment Video
Updated: Jan 21, 2026

Constructing and Visualizing Models using Mime-based Machine-learning Framework
Published on: July 22, 2025
A predictive integrated framework based on the radial basis function for the modelling of the flow of pharmaceutical
Maen Alshafiee1, Wafa' H AlAlaween2, Daniel Markl3
1Department of Pharmacy, University of Huddersfield, Queensgate, Huddersfield HD1 3DH, UK.
Abstract:
This study presents a modelling framework to predict the flowability of various commonly used pharmaceutical powders and their blends. The flowability models were trained and validated on 86 samples including single components and binary mixtures. Two modelling paradigms based on artificial intelligence (AI) namely, a radial basis function (RBF) and an integrated network were employed to model the flowability represented by the flow function coefficient (FFC) and the bulk density (RHOB). Both approaches were utilized to map the input parameters (i.e. particle size, shape descriptors and material type) to the flow properties. The input parameters of the blends were determined from the particle size, shape and material type properties of the single components. The results clearly indicated that the integrated network outperformed the single RBF network in terms of the predictive performance and the generalization capabilities. For the integrated network, the coefficient of determination of the testing data set (not used for training the model) for FFC was R2=0.93, reflecting an acceptable predictive power of this model. Since the flowability of the blends can be predicted from single component size and shape descriptors, the integrated network can assist formulators in selecting excipients and their blend concentrations to improve flowability with minimal experimental effort and material resulting in the (i) minimization of the time required, (ii) exploration and examination of the design space, and (iii) minimization of material waste.
Related Concept Videos
Pharmaceutical Equivalents
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Predicting Molecular Geometry
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Growth Models with Integration: Problem Solving
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

