Related Experiment Video
Updated: Jan 21, 2026

The Perinatal Asphyxiated Lamb Model: A Model for Newborn Resuscitation
Published on: August 15, 2018
Novel technologies for heart rate assessment during neonatal resuscitation at birth - A systematic review
Peter A Johnson1, Po-Yin Cheung1, Tze-Fun Lee1
1Centre for the Studies of Asphyxia and Resuscitation, Neonatal Research Unit, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
Background:
6.5-9 million newborns worldwide require resuscitation at birth annually. During neonatal resuscitation, inaccurate or slow heart rate (HR) assessments may significantly increase risk of infant mortality or morbidity. Therefore fast, accurate, and effective HR assessment tools are critical for neonatal resuscitation.
Objective:
To systematically review the literature about accuracy, latency, and efficacy of technologies for HR assessment during neonatal resuscitation.
Methods:
Adhering to PRISMA guidelines, PubMed, EMBASE, and Google Scholar databases were systematically searched to identify studies related to technologies for HR assessment, which could be used to guide neonatal resuscitation.
Results:
Forty-six studies evaluating HR assessment technologies for neonatal resuscitation were identified. In total, 16 studies (3/16 randomized trials and 13/16 observational studies) compared two or more HR assessment technologies to measure accuracy, latency, and efficacy. Of the trials, 1/3 had a low risk of bias while 2/3 had high risks. All observational studies had high risks of bias. Most studies considered infants not requiring resuscitation, constituting indirect evidence and lower certainty in the context of neonatal resuscitation. Two trials reported faster times to HR assessment using electrocardiogram with a mean(SD) 66(20) versus 114(39) s and a median(IQR) 24(19-39) versus 48(36-69) s (both p < 0.001), compared to pulse oximetry.
Conclusion:
While electrocardiography is faster to assess HR at birth and more reliable to detect HR changes compared to other recommended technologies, practice should not exclusively rely on ECG. While novel technologies could support HR assessment, no studies validate their clinical efficacy during neonatal resuscitation.
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Birth Control Methods
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

