Related Experiment Video
Updated: Jan 21, 2026

Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection
Published on: May 13, 2019
Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide
Nongyao Nontawong1, Maliwan Amatatongchai1, Suphatsorn Thimoonnee1
1Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Abstract:
We report a novel amperometric flow-injection (FI) analysis of creatinine based on a sensor comprising copper oxide nanoparticles (CuO) coated with a molecularly-imprinted polymer (CuO@MIP) and decorating a carbon-paste electrode (CPE) to form the CuO@MIP/CPE electrode. The CuO@MIP was synthesized by using CuO as the supporting core, creatinine as the template, methacrylic acid (MAA) as monomer, N, N'-(1,2-dihydroxyethylene)bis(acrylamide) (DHEBA) as cross-linker, and 2,2'-azobis (2-methylpropionitrile) (AIBN) as initiator. Morphology and structural characterization reveal that CuO nanoparticle imprinted sites (CuO) synthesized using a precipitation method, exhibits features that are well suited to creatinine detection: high surface area, good analyte diffusion and adsorption characteristics that provide shorter response times, and large numbers of specific cavities for enhanced analyte capacity and sensitivity. Cyclic voltammetric measurements indicate that our sensor provides excellent performance toward electro-oxidation of creatinine. The amperometric FI system was used to quantitatively determine creatinine at the CuO@MIP/CPE sensor, in a phosphate buffer carrier. The imprinted sensor exhibits excellent performance for creatinine oxidation at an applied potential of +0.35 V and flow rate of 0.6 mL.min-1. The as-prepared sensor exhibits a linear dynamic range for creatinine detection from 0.5 to 200 μM (r2 = 0.995) with a limit of detection of 0.083 μM (S/N = 3). The system exhibits satisfactorily good precision (%RSD = 1.94%, n = 30) and selectivity toward creatinine. There is only approximately 20% loss from initial response after 2 weeks when stored at 4 oC. We successfully applied the FI detection system to detect creatinine in human urine samples.
Related Concept Videos
Imprinting
Standard Electrode Potentials
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Polymers: Defining Molecular Weight
The number average molecular weight (Mn) is the summation of the number...
Polymers: Molecular Weight Distribution
Polymers