The Effect of Degradation of Soda Lignin Using Pd/SO42-/ZrO2 as a Catalyst: Improved Reactivity and Antioxidant

Shengming Zhang1,2, Guizhen Fang3, Haitao Chen4

  • 1College of Engineering, Northeast Agricultural University, Harbin 150030, China. zsmdblydx@163.com.

Polymers
|July 24, 2019
PubMed

Related Concept Videos

Regulated Protein Degradation02:58

Regulated Protein Degradation

It is vital to regulate the activity of enzymatic as well as non-enzymatic proteins inside the cell. This can be achieved either through creating a balance between their rate of synthesis and degradation or regulating the intrinsic activity of the protein. Both these regulation mechanisms play an essential role in the normal functioning of cells.
Protein degradation plays two important roles in the cells. It helps to protect cells from misfolded or damaged proteins before they lead to a...
8.8K
Regulated Protein Degradation02:58

Regulated Protein Degradation

3.1K
Proteins: From Genes to Degradation02:11

Proteins: From Genes to Degradation

Within a biological system, the DNA encodes the RNA, and the nucleotide sequence in the RNA further defines the amino acid sequence in the protein. This is referred to as “The Central Dogma of Molecular Biology” - a term coined by Francis Crick.  Central dogma is a firm principle in biology that defines the flow of genetic information within any life form. The two fundamental steps in central dogma are - transcription and translation.
Transcription is the synthesis of RNA...
14.2K
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
630
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
383
Activation Energy01:26

Activation Energy

Activation energy is the minimum amount of energy necessary for a chemical reaction to move forward. The higher the activation energy, the slower the rate of the reaction. However, adding heat to the reaction will increase the rate, since it causes molecules to move faster and increase the likelihood that molecules will collide. The collision and breaking of bonds represents the uphill phase of a reaction and generates the transition state. The transition state is an unstable high-energy state...
86.4K