Related Experiment Video
Updated: Jan 21, 2026

08:20
In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
7.4K
Bare Soil Surface Moisture Retrieval from Sentinel-1 SAR Data Based on the Calibrated IEM and Dubois Models Using
Hamid Reza Mirsoleimani1, Mahmod Reza Sahebi2, Nicolas Baghdadi3
1Faculty of Geodesy and Geomatics Engineering & Remote Sensing Institute, K. N. Toosi University of Technology, Tehran 19667-15433, Iran.
Sensors (Basel, Switzerland)
|July 24, 2019
Summary
This study evaluated radar backscattering models for agricultural areas. The calibrated integral equation model (CIEM) showed better performance than the modified Dubois model (MDB) for soil moisture estimation using Sentinel-1 data.
Area of Science:
- Remote Sensing
- Geophysics
- Agricultural Science
Background:
- Radar backscattering models are crucial for analyzing Earth's surface.
- Accurate soil moisture estimation is vital for agricultural management and hydrological studies.
- Assessing model performance and retrieval techniques using satellite data is an ongoing research area.
Purpose of the Study:
- To evaluate the performance of the calibrated integral equation model (CIEM) and the modified Dubois model (MDB) for radar backscattering over an agricultural region in Karaj, Iran.
- To estimate soil surface moisture using CIEM and MDB with single-polarization Sentinel-1 images via neural networks.
- To determine the effectiveness of different polarizations for soil moisture retrieval.
Main Methods:
- Field measurements were used to validate the performance of CIEM and MDB.
- Neural networks (NNs) were employed for inverting soil moisture from backscattering coefficients.
- Single-polarization Sentinel-1 Synthetic Aperture Radar (SAR) data were utilized for soil moisture estimation.
Main Results:
- The calibrated integral equation model (CIEM) achieved a lower root mean square error (RMSE) of 0.78 dB compared to the modified Dubois model (MDB) with 1.45 dB.
- Neural network-based inversion demonstrated the efficiency of single-polarized Sentinel-1 data for retrieving soil surface moisture.
- VV polarization proved particularly effective for soil moisture retrieval.
Conclusions:
- The calibrated integral equation model (CIEM) is a more accurate model for radar backscattering over agricultural areas compared to MDB.
- Single-polarized Sentinel-1 data, especially VV polarization, can be effectively used with neural networks for soil moisture estimation.
- The findings support the use of radar remote sensing for agricultural monitoring and water resource management.
Related Concept Videos
The Soil Ecosystem
24.6K
Plants obtain inorganic minerals and water from the soil, which acts as a natural medium for land plants. The composition and quality of soil depend not only on the chemical constituents but also on the presence of living organisms. In general, soils contain three major components:
24.6K
Retrieval
422
Retrieval is the process of getting information out of memory storage and back into conscious awareness. This ability is essential for daily tasks like brushing hair and teeth, driving to work, and performing job duties. Retrieval occurs in three ways: recall, recognition, and relearning.
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
422
Glassware Calibration
1.3K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.3K
Protein Networks
4.5K
An organism can have thousands of different proteins, and these proteins must cooperate to ensure the health of an organism. Proteins bind to other proteins and form complexes to carry out their functions. Many proteins interact with multiple other proteins creating a complex network of protein interactions.
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
4.5K
ER Retrieval Pathway
4.7K
In the secretory pathway, vesicles transport proteins from one cellular compartment to another in forward transport to deliver the protein to its correct location. Occasionally, misfolded proteins and incorrect proteins escape their original compartments, and a retrieval pathway is used to return the escaped proteins to their original compartment.
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
4.7K
Instrument Calibration
690
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
690

