Related Experiment Video
Updated: Jan 21, 2026

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
All-arthroscopic, guided Eden-Hybbinette procedure using suture-button fixation for revision of failed Latarjet
Pascal Boileau1, Christophe Duysens2, David Saliken1
1iULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d'Azur, Nice, France.
Purpose:
To report the results of a guided arthroscopic Eden-Hybbinette procedure, using suture button for iliac crest bone graft fixation, in a series of patients with a prior failed Latarjet and persistent glenoid bone loss.
Methods:
Seven consecutive patients (5 males, 2 females, mean age: 30.7 years [range, 17-47 years]) with recurrent anterior dislocations and glenoid deficiency greater than 20% underwent the all-arthroscopic revision procedure. The iliac crest bone graft and suture-button device (Bone-Link) were shuttled through the rotator interval. Specific drill guides were used and a suture tensioning device allowed bone graft compression. Previous broken screw shafts (3 patients) were left in situ. Graft placement and healing was assessed postoperatively with computed tomography imaging.
Results:
No neurologic injury or hardware problems occurred, and no patient required further surgery. On computed tomography scan, optimal positioning (flush and under the equator) and healing of the bone graft was observed in all patients. At a mean follow-up of 21 months (range, 12-39 months), all but one patient were satisfied and had a stable shoulder; 5 returned to sports. The Constant score increased from 32 to 81 points, and the subjective shoulder value from 31% to 87% (P < .001). The Walch-Duplay and Rowe scores averaged 85.7 (range, 65-100) points and 86.4 (range, 70-100) points, respectively.
Conclusion:
Recurrence of anterior shoulder instability after a failed Latarjet procedure can be successfully treated by an all-arthroscopic Eden-Hybbinette procedure. Suture-button fixation is reliable and permits optimal positioning and predictable healing of the new bone graft; in addition, it is an appropriate fixation option in the setting of retained broken hardware.
Related Concept Videos
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Blind Procedures
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...

