Related Experiment Video
Updated: Jan 21, 2026

Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
Factors affecting salivary α-amylase levels measured with a handheld biosensor and a standard laboratory assay
Kanlayanee Tangprasert1, Nattinee Jantaratnotai2, Praewpat Pachimsawat1
1Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
Objectives:
A handheld biosensor for measuring salivary α-amylase (sAA) was developed for convenient on-site measurement. Previous studies reported some discrepancies in sAA levels measured with a biosensor and a standard assay. This study aimed to compare sAA levels measured with three different methods and the factors affecting its levels.
Methods:
Thirty-eight participants collected saliva two times for three measurements. First, the collector strip was placed under the tongue for 2 minutes, then the strip was used to measure sAA level on-site immediately (intraoral biosensor; method 1). Then, a participant pooled the saliva for 4 minutes and collected the saliva into the tube which was aliquoted to measure in a laboratory with a handheld biosensor (extraoral biosensor; method 2) and with a standard enzyme kinetic assay (EKA; method 3). Additional experiments were carried out to compare the levels of sAA measured with differences in pooling time and positioning of the collector strip.
Results:
A high correlation of sAA levels between an extraoral and an EKA measurement (r = 0.989) was observed, while sAA levels measured with an intraoral method showed a significant but weaker correlation with either an EKA (r = 0.475) or an extraoral method (r = 0.436). Saliva pooling time and positioning of the collector strip significantly affected sAA levels.
Conclusions:
A handheld biosensor is valid to measure sAA levels extraorally. For an intraoral measurement, pooling time and positioning of the collector strip need to be taken into account.
More Related Videos
Related Concept Videos
Measurement: Standard Units
Factors Affecting α-Alkylation of Ketones: Choice of Base
The reaction involving bases like EtO− whose conjugate acid EtOH (pKa = 15.9) is stronger than the ketone (pKa = 19.2) results in an equilibrium mixture with higher ketone concentration. As a consequence,...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Units and Standards of Measurement
Measurements of physical quantities are...
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...

