Microhardness distribution of the tibial diaphysis and test site selection for reference point indentation technique
Jianzhao Wang1,2, Bing Yin1,2, Guobin Liu1,2
1Department of Orthopaedic Surgery, The Third Hospital of Hebei Medical University.
Abstract:
Indentation hardness test is a good in vitro method of bone quality assessment. The purpose of this study is to explore the distribution characteristics of bone tissue microhardness in tibial diaphysis and provide theoretical support for the test site selection of the reference point indentation technique.Three fresh right tibias were obtained from 3 cadaver donors. The tibial diaphysis was evenly divided into 6 sections. Bone specimens with a thickness of 3 mm were cut from each part. After appropriate management, micro-indentation tests were performed in various regions of the specimens to acquire the microhardness values of the tibial diaphysis. Statistical analysis was performed by randomized block design variance analysis to study the distribution characteristics of bone microhardness.72 regions were selected for 360 effective indentations. We found that the bone microhardness is inhomogeneous in tibia diaphysis. Mean hardness value of the anterior, medial, posterior, lateral region of tibia diaphysis was 45.58 ± 4.39 Vickers hardness (HV), 52.33 ± 3.93 HV, 54.00 ± 4.21 HV, 52.89 ± 4.44 HV, respectively. The anterior cortex exhibits lower microhardness value than the other regions (P < .001). Within the same region, microhardness varies significantly with positions in the tibial diaphysis. The variations in indentation hardness are bound to have a significant impact on the comparability of different reference point indentation (RPI) studies.The results of this study indicated the regional microhardness difference in the human tibia diaphysis. The microhardness of different planes in the same region is also inconsistent. Inhomogeneous distribution of indentation microhardness would have considerable influence in the test site selection of RPI technique. The data collected in our study would contribute to the design of highly precise 3D printing implants and bionic bones with gradient elastic modulus.
Related Concept Videos
Inertial Frames of Reference
Non-inertial Frames of Reference
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Drug Distribution: Volume of Distribution
F Distribution
What is Natural Selection?