Related Experiment Video
Updated: Jan 21, 2026

A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015
Comparison of VITEK® 2, three different gradient strip tests and broth microdilution for detecting vanB-positive
Ingo Klare1, Jennifer K Bender1, Carola Fleige1
1National Reference Centre for Staphylococci and Enterococci (NRC), Division of Nosocomial Pathogens and Antibiotic Resistance, Department of Infectious Diseases, Robert Koch Institut, Wernigerode Branch, Wernigerode, Germany.
Objectives:
In 2018, EUCAST issued a warning regarding unreliable results of gradient strip tests for confirming vancomycin resistance in enterococci. We compared the performance of various diagnostic standard and confirmatory tests to identify and determine vanB-type vancomycin resistance.
Methods:
We analysed a collection of vanB-positive Enterococcus faecium isolates (n = 68) with low vancomycin MICs and compared the performance of VITEK® 2 (bioMérieux), broth microdilution and three gradient strip tests from different providers (Oxoid, Liofilchem and bioMérieux). For the latter we compared the standard procedure with a protocol with increased inoculum, a rich agar medium and a longer incubation time ('macromethod').
Results:
The sensitivity of VITEK® 2 was 81% compared with 72% for broth microdilution and 61%-63% for the three gradient strip tests using standard conditions. The macromethod substantially improved the performance of all strip tests resulting in a sensitivity of 89%-96% after 48 h of incubation.
Conclusions:
We recommend that EUCAST changes the present warning against the general use of MIC strips. When MIC strips are used to either exclude or confirm suspected vancomycin resistance in E. faecium, and a PCR is not available, the macromethod should be employed. For clinically relevant enterococci, where a rapid therapeutic decision is needed, a molecular test (e.g. PCR) should be favoured in order to save time and to further increase sensitivity.
More Related Videos
08:54Broth Microdilution In Vitro Screening: An Easy and Fast Method to Detect New Antifungal Compounds
Published on: February 14, 2018
12:39Antimicrobial Susceptibility Testing of Mycobacterium Tuberculosis Complex for First and Second Line Drugs by Broth Dilution in a Microtiter Plate Format
Published on: June 24, 2011
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Position-effect Variegation
Serial Position Effect