Effect of Interocular Contrast Difference on Stereopsis in Observers With Sensory Eye Dominance
Chao Han1, Zijiang J He2, Teng Leng Ooi1
1College of Optometry, The Ohio State University, Columbus, Ohio, United States.
Purpose:
We investigated how sensory eye dominance (SED) affects stereopsis when the half-images of random-dot-stereo stimuli had different interocular contrast.
Methods:
We measured crossed and uncrossed stereo disparity thresholds and reaction time to seeing random-dot-stereograms with variable interocular contrast differences (ICD), where ICD = (log10 [CLE] - log10 [CRE]) = -0.4, -0.2, 0, 0.2, or 0.4 log unit. The mean contrast of the stimuli, (log10 [CLE] + log10 [CRE])/2, remained constant at 1.2 log unit to ensure that the measured effect was solely due to ICD. We also measured SED using, respectively, dichoptic horizontal sine wave gratings with different phases (revealing SEDcombo) and dichoptic vertical and horizontal gratings (revealing SEDinhibition).
Results:
Both measures of SEDinhibition and SEDcombo revealed the observers had the same eye as dominant although the magnitudes differed. The observers had lower stereo thresholds and shorter stereo reaction time on stimuli with unequal interocular contrast when the non-sensory-dominant eye viewed the higher contrast half-image, suggesting a stimulus-compensating effect. We then estimated the ICD of random-dot-stereo half-images (compensating stimuli) that would lead to minimum stereo threshold (SEDstereo-threshold) and reaction time (SEDstereo-RT) based on the stereo performance and ICD relationship, and found that they were significantly smaller than SEDinhibition and SEDcombo.
Conclusions:
By linking SEDinhibition and SEDcombo with the effect of ICD on stereopsis, we provided further support for the notion that the stimulus-compensating effect is mediated by the interocular inhibitory and interocular gain control mechanisms. Furthermore, the interocular contrast for SEDstereo-threshold and SEDstereo-RT can be potentially applied for improving stereopsis in individuals with SED.
Related Concept Videos
What is a Sensory System?
Incomplete Dominance
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Naturalistic Observations