Consequence of insertion trauma - effect on early measurements when using intracerebral devices
Ted Carl Kejlberg Andelius1, Mette Vestergård Pedersen2, Nikolaj Bøgh3
1Department of Paediatrics, Aarhus University Hospital, Palle Juul-Jensens Blvd. 99, 8200, Aarhus N, Denmark. ted.andelius@clin.au.dk.
Abstract:
There are a variety of devices that quantify biological properties of cerebral tissue. Installing such device will cause a local insertion trauma, which will affect early measurements. Current literature proposes minimum one hour of observation before acquiring first measurements when using microdialysis. It is unknown whether this applies to other intracerebral devices. We therefore aimed to investigate time needed to reach steady state when using microdialysis and two intracerebral probes in a piglet model. Ten newborn piglets less than 24 hours of age were anaesthetized. Two probes (Codman and OxyLite/OxyFlo) and a microdialysis catheter (CMA Microdialysis) were installed 10 mm into the left hemisphere. Probes measured intracranial pressure, cerebral blood flow, and oxygen tension. The microdialysis catheter measured lactate, glucose, glycerol, and pyruvate. Measurements were acquired hourly for 20 hours. Lactate and glycerol peaked immediately after insertion and reached steady state after approximately four hours. Glucose, pyruvate, cerebral blood flow, and intracranial pressure reached steady state immediately. Oxygen tension reached steady state after 12 hours. With time, interindividual variability decreased for the majority of measurements. Consequently, time to stabilization after insertion depends on the choice of device and is crucial to obtain valid baseline values with high degree of precision.
Related Concept Videos
Timing and Consequences on Behavior
Humans, however, can respond to delayed reinforcers. We often make decisions between immediate small rewards and delayed larger rewards. This ability to delay gratification is a significant...
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Insertion of Multi-pass Transmembrane Proteins in the RER
The multipass transmembrane proteins are the type IV integral membrane proteins with multiple topogenic sequences determining their spatial arrangement in the ER membrane. Nearly all multipass proteins lack a cleavable signal sequence and use...