Mimicking the cauda epididymal plasma-like osmolality in extender improves liquid preservation of ram semen at 3-5°C

Rajani Kumar Paul1, Krishnappa Balaganur1, Davendra Kumar1

  • 1Semen Cryobiology Laboratory, Division of Animal Physiology and Biochemistry, ICAR-Central Sheep and Wool Research Institute, Jaipur, India.

Related Concept Videos

Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists01:27

Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists

5-HT3 receptor antagonists, such as dolasetron, granisetron (Kytril), ondansetron (Zofran), and palonosetron (Axoli), are crucial in managing chemotherapy-induced nausea and vomiting (CINV) and postoperative nausea. These drugs selectively block 5-HT3 receptors in the visceral vagal and spinal afferent nerves, chemoreceptor trigger zone, and the vomiting center. They have a rapid onset of action and can be given as a single dose before chemotherapy. Ondansetron and granisetron, in particular,...
608
Sperm Structure and Semen Composition01:22

Sperm Structure and Semen Composition

During ejaculation, males release around 2-5 milliliters of semen, which is a complex mixture of mature sperm and various fluids produced by accessory glands. The mature sperm cells measure approximately 60 micrometers in length and consist of a head, neck, midpiece, and tail. The head is flattened and tapered, measuring about 4 to 5 micrometers in length. It contains a nucleus with condensed chromosomes and an acrosome, a cap-like structure filled with enzymes essential for penetrating the...
10.7K
5-Number Summary01:04

5-Number Summary

In a dataset, the 5-number summary includes the minimum data value, the data value of the first quartile, the median data value or data value of the second quartile, the data value of the third quartile, and the maximum data value. These 5 data values can be visualized as a box and whisker plot.
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
5.5K
Gravitational Potential Energy for Extended Objects01:07

Gravitational Potential Energy for Extended Objects

Consider a system comprising several point masses. The coordinates of the center of mass for this system can be expressed as the summation of the product of each mass and its position vector divided by the total mass:
1.9K
Composition of Blood Plasma01:24

Composition of Blood Plasma

Blood plasma is a fluid that contains approximately 92% water and 8% solutes. The solutes include various types of proteins, which constitute about 7% of the total solutes in the plasma. The high-molecular-weight proteins—albumins, globulins, and fibrinogen—are essential to plasma function. Albumins, making up about 60% of the plasma proteins, maintain the osmotic balance within blood vessels by preventing excessive water leakage. Additionally, albumins serve as carrier proteins,...
7.9K
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH301:11

ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3

All ortho–para directors, excluding halogens, are activating groups. These groups donate electrons to the ring, making the ring carbons electron-rich. Consequently, the reactivity of the aromatic ring towards electrophilic substitution increases. For instance, the nitration of anisole is about 10,000 times faster than the nitration of benzene. The electron-donating effect of the methoxy group in anisole activates the ortho and para positions on the ring and stabilizes the corresponding...
7.3K