Projection-based improvement of 3D reconstructions from motion-impaired dental cone beam CT data
Stefan Niebler1, Elmar Schömer1, Henning Tjaden2
1Institute of Computer Science, Johannes Gutenberg University, 55099, Mainz, Germany.
Purpose:
Computed tomography (CT) and, in particular, cone beam CT (CBCT) have been increasingly used as a diagnostic tool in recent years. Patient motion during acquisition is common in CBCT due to long scan times. This results in degraded image quality and may potentially increase the number of retakes. Our aim was to develop a marker-free iterative motion correction algorithm that works on the projection images and is suitable for local tomography.
Methods:
We present an iterative motion correction algorithm that allows the patient's motion to be detected and taken into account during reconstruction. The core of our method is a fast GPU-accelerated three-dimensional reconstruction algorithm. Assuming rigid motion, motion correction is performed by minimizing a pixel-wise cost function between all captured x-ray images and parameterized projections of the reconstructed volume.
Results:
Our method is marker-free and requires only projection images. Furthermore, it can deal with local tomography data. We demonstrate the effectiveness of our approach on both simulated and real motion-beset patient images. The results show that our new motion correction algorithm leads to accurate reconstructions with sharper edges, better contrasts and more detail.
Conclusions:
The presented method allows for correction of patient motion with observable improvements in image quality compared to uncorrected reconstructions. Potentially, this may reduce the number of retakes caused by corrupted reconstructions due to patient movements.
Related Concept Videos
Fischer Projections
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Newman Projections
The organic molecules rotate across the single bonds leading to numerous temporary three-dimensional structures of varying energy known as...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Coordinates and Map Projections
Equation of Motion: General Plane motion
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...