Related Experiment Video
Updated: Jan 21, 2026

A Customizable Protocol for String Assembly gRNA Cloning STAgR
Published on: December 26, 2018
Quantitative assessment of LASSO probe assembly and long-read multiplexed cloning
Syukri Shukor1, Alfred Tamayo1, Lorenzo Tosi1
1Center for Surgery, Innovation, and Bioengineering, Department of Surgery, Massachusetts General Hospital, Harvard Medical School and the Shriners Hospitals for Children, 51 Blossom Street, Boston, MA, 02114, USA.
Background:
Long Adapter Single-Stranded Oligonucleotide (LASSO) probes were developed as a novel tool for massively parallel cloning of kilobase-long genomic DNA sequences. LASSO dramatically improves the capture length limit of current DNA padlock probe technology from approximately 150 bps to several kbps. High-throughput LASSO capture involves the parallel assembly of thousands of probes. However, malformed probes are indiscernible from properly formed probes using gel electrophoretic techniques. Therefore, we used next-generation sequencing (NGS) to assess the efficiency of LASSO probe assembly and how it relates to the nature of DNA capture and amplification. Additionally, we introduce a simplified single target LASSO protocol using classic molecular biology techniques for qualitative and quantitative assessment of probe specificity.
Results:
A LASSO probe library targeting 3164 unique E. coli ORFs was assembled using two different probe assembly reaction conditions with a 40-fold difference in DNA concentration. Unique probe sequences are located within the first 50 bps of the 5' and 3' ends, therefore we used paired-end NGS to assess probe library quality. Properly mapped read pairs, representing correctly formed probes, accounted for 10.81 and 0.65% of total reads, corresponding to ~ 80% and ~ 20% coverage of the total probe library for the lower and higher DNA concentration conditions, respectively. Subsequently, we used single-end NGS to correlate probe assembly efficiency and capture quality. Significant enrichment of LASSO targets over non-targets was only observed for captures done using probes assembled with a lower DNA concentration. Additionally, semi-quantitative polyacrylamide gel electrophoresis revealed a ~ 10-fold signal-to-noise ratio of LASSO capture in a simplified system.
Conclusions:
These results suggest that LASSO probe coverage for target sequences is more predictive of successful capture than probe assembly depth-enrichment. Concomitantly, these results demonstrate that DNA concentration at a critical step in the probe assembly reaction significantly impacts probe formation. Additionally, we show that a simplified LASSO capture protocol coupled to PAGE (polyacrylamide gel electrophoresis) is highly specific and more amenable to small-scale LASSO approaches, such as screening novel probes and templates.
Related Concept Videos
Reproductive Cloning
Somatic Cell Nuclear Transfer
In SCNT, an egg cell is taken from an animal and its nucleus is removed, creating an enucleated egg. Then a somatic...
Uncertainty in Measurement: Reading Instruments
Cloning of Dolly the Sheep
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
Spindle Assembly
In most cells, centrosomes are the primary microtubule nucleation centers. In the centrosome-mediated pathway, the G2-prophase transition triggers centrosome maturation and increased microtubule nucleation. Progressive nucleation results in a...
Oligosaccharide Assembly
Multiple sugar molecules that may or may...

