Related Experiment Video
Updated: Jan 21, 2026

The Multiple Sclerosis Performance Test MSPT: An iPad-Based Disability Assessment Tool
Published on: June 30, 2014
CEST MRI with distribution-based analysis for assessment of early stage disease activity in a mouse model of multiple
Tao Liu1,2,3, Yanrong Chen1,3,4, Aline M Thomas1,3
1Russell H. Morgan Dept. of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, Maryland.
Abstract:
Imaging biomarkers that can detect pathological changes at an early stage of multiple sclerosis (MS) may allow earlier therapeutic intervention with an improved outcome. Using a mouse model of MS, termed as experimental autoimmune encephalomyelitis (EAE), we performed chemical exchange saturation transfer (CEST) MRI at a very early stage before symptom onset (6 days post-induction) for assessment of changes in tissues that appear "normal" with conventional MRI. The collected CEST Z-spectra signals (Ssat /S0 ) were analyzed using a histogram-guided method to determine the contributions from various offset frequencies. Histogram analysis showed that EAE mice exhibit a more heterogeneous distribution with lower peak heights in the hindbrain compared with naïve mice at saturation offsets of 1 and 2 ppm. At these two offsets, both the mean Ssat /S0 and the mean MTRasym values in the cerebellum and brain stem are significantly different between EAE and naïve mice (P < 0.05). Immunofluorescent staining validated the presence of neuroinflammation, with IBA1-positive cells detected throughout the hindbrain including the cerebellum and brain stem. Follow-up MRI at the symptom onset (score = 1.5-2.5, 13 days post-induction) confirmed gadolinium-enhanced periventricular lesions. CEST Z-spectra signals also changed by this time. The proposed three-level histogram-oriented analysis is simple to execute and robust for detecting subtle changes in Z-spectra signals, which does not require a priori knowledge of damage locations or contributing offset components. CEST MRI signals at 1 and 2 ppm were sensitive to the subtle pathological changes at an early stage in EAE mice, and have potential as novel imaging biomarkers complementary to functional and physiological MRI measures.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Bioavailability Study Design: Single Versus Multiple Dose Studies

