Related Experiment Video
Updated: Jan 21, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Impact of aging on semiquantitative uptake parameters in normal rated clinical baseline [123I]Ioflupane single photon
Rudolf A Werner1,2,3, Constantin Lapa3, Sara Sheikhbahaei1
1Division of Nuclear Medicine and Molecular Imaging, The Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Objectives:
Studies investigating the age-related impact on dopamine transporter binding have previously omitted the use of attenuation correction by computed tomography (CT). We aimed to explore the impact of age and gender on dopamine transporter binding on [I]Ioflupane single photon emission CT (SPECT) imaging with simultaneously acquired CT.
Methods:
Three hundred forty-two patients with clinically uncertain parkinsonian syndrome underwent [I]-Ioflupane SPECT/CT with CT-based attenuation correction. Two nuclear medicine physicians independently performed a visual evaluation of all scans and only visibly normal scans were included for further analysis. Moreover, the results of a fully automatic semiquantitative evaluation method were recorded. Thereafter, the obtained [I]Ioflupane binding ratio and the hemispheric asymmetry index were correlated with age and sex.
Results:
Patient age range was 41-80 years with a balanced distribution over decades. Of 342 patients, 133 (38.9%, 66 females, median age, 64 years) were considered visually normal by both observers on the SPECT/CT images. A significant inverse correlation between age and [I]Ioflupane binding ratios in the striata (R = -0.38; P < 0.001), putamina (R = -0.39; P < 0.001) and caudate nuclei (R = -0.3; P < 0.001) was demonstrated. Linear regression of all included subjects demonstrated an average decrease of 0.19 per decade in the striatal binding ratio (6.6%). No significant sex differences were found in striatal binding ratios (P = 0.86). Moreover, no significant correlation was observed between age and striatal asymmetry index (r = 0.12; P = 0.16).
Conclusion:
In the present largest single-center analysis investigating [I]Ioflupane SPECT/CT in patients with clinical uncertain parkinsonian syndrome, a dopamine transporter loss of 6.6% per decade in visually normal scans was recorded.
More Related Videos
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations