Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Development and Application of SERS Flexible Substrates Using Synthesized AgNPs
Published on: November 17, 2023
Utilization of doped GQDs for ultrasensitive detection of catastrophic melamine: A new SERS platform
Vaishali Sharma1, Narayan N Som1, Sharad Babu Pillai1
1Department of Physics, Faculty of Science, The M. S. University of Baroda, Vadodara, Gujarat 390002, India.
Abstract:
The detection and filtration of melamine in food products has become an emergence due to its harmful effect on humans. In present work, we have investigated the binding mechanism of melamine over carboxyl group edge-functionalized graphene quantum dots doped with oxygen and sulphur atoms (O-GQD and S-GQD). In order to monitor melamine, surface enhanced Raman scattering (SERS) is adopted which is an effective vibrational spectroscopic approach. Electronic and vibrational properties were analysed by means of well adapted density functional theory (DFT). The calculated adsorption energy of melamine over O-GQD and S-GQD is -1.18 and -0.15 eV respectively. The characteristic peak of melamine at 688 cm-1 is in good agreement with previously reported experimental work and enhances by 348.4% in SERS spectra of Mel-O-GQD and 48% in SERS spectra of Mel-S-GQD. We have calculated the chemical enhancement factor (EF) for melamine over O-GQD and S-GQD and found the enhancement of 4.51 and 1.48 which is greater than melamine‑silver complexes. Our theoretical studies on SERS of melamine over O-GQD and S-GQD suggest that oxygen is a better candidate for SERS. Our work demonstrates that the graphene quantum dots are remarkable platforms for the detection of melamine.
More Related Videos
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
10:02Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril
Published on: October 3, 2020
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...