Related Experiment Video
Updated: Jan 21, 2026

Retzius-Sparing Robot-Assisted Radical Prostatectomy
Published on: May 19, 2022
Comparison of various continence definitions in a large group of patients undergoing radical prostatectomy: a
Sigrun Holze1, Meinhard Mende2, Karl V Healy3
1Department of Urology, University of Leipzig, Liebigstr. 20, 04103, Leipzig, Germany. sigrun.holze@medizin.uni-leipzig.de.
Background:
Due to the usage of various measurement methods and definitions, comparing continence rates after radical prostatectomy is a challenging task. This study compares continence rates based on different methods and aims to identify the definition for continence which agrees best with the patients' subjective assessment of continence. Additionally, continence was controlled for multiple influencing factors.
Methods:
This prospective multicentre study was carried out in seven hospitals throughout Germany. Before and at 3, 6, and 12 months after surgery self-reporting questionnaires were completed and returned by 329 (84.4%) of 390 eligible patients. The questionnaires were independently evaluated and analysed by a third party. Association of continence with demographic, operative, and tumour factors in an ongoing comprehensive prostate cancer database was evaluated.
Results:
The continence rate drops substantially for patients undergoing radical prostatectomy but increases again with time. Concrete numbers vary considerably depending on definition - 44% at 3 months and 68% at 12 months after surgery (0 pads) vs. 71 and 90% (0-1 pads). Significant confounding variables regarding continence rate are nerve-sparing procedure, categorized Gleason score, rehabilitative cure treatment, and pelvic floor training. The definition of 0 pads for continence coincides greater than 0-1 pads with the patients' self-assessment of being continent.
Conclusion:
A standardized definition for continence would be desirable, as it is one of the most important preconditions to guarantee sound comparison of continence rates. Since there are enough other factors that make comparison difficult, we suggest using the definition of "0 pads". It is easily measured objectively, leaves no room for interpretation, and agrees best with the patients' self-assessment.
More Related Videos
Related Concept Videos
Definite Integral
Molecular Comparison of Gases, Liquids, and Solids
Definition of z-Transform
Radical Reactivity: Nucleophilic Radicals
Radical Reactivity: Electrophilic Radicals
The Sense of Self: Reflected Self-Appraisal and Social Comparison

