Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Accurate 1H-14N distance measurements by phase-modulated RESPDOR at ultra-fast MAS
Nghia Tuan Duong1, Federica Rossi2, Maria Makrinich3
1NMR Science and Development Division, RIKEN SPring-8 Center, and Nano-Crystallography Unit, RIKEN-JEOL Collaboration Center, Yokohama, Kanagawa 230-0045, Japan.
Abstract:
The combination of a phase-modulated (PM) saturation pulse and symmetry-based dipolar recoupling into a rotational-echo saturation-pulse double-resonance (RESPDOR) sequence has been employed to measure 1H-14N distances. Such a measurement is challenging owing to the quadrupolar interaction of 14N nucleus and the intense 1H-1H homonuclear dipolar interactions. Thanks to the recent advances in probe technology, the homonuclear dipolar interaction can be sufficiently suppressed at a fast MAS frequency (νR ≥ 60 kHz). PM pulse is robust to large variations of parameters on quadrupolar spins, but it has not been demonstrated under very fast MAS conditions. On the other hand, the RESPDOR sequence is applicable to such condition when it employs symmetry-based pulses during the recoupling period, but a prior knowledge on the system is required. In this article, we demonstrated the PM-RESPDOR combination for providing accurate 1H-14N distances at a very fast MAS frequency of 70 kHz on two samples, namely L-tyrosine⋅HCl and N-acetyl-L-alanine. This sequence, supported by simulations and experiments, has shown its feasibility at νR = 70 kHz as well as the robustness to the 14N quadrupolar interaction. It is applicable to a wide range of 1H-14N dipolar coupling constants when a radio frequency field on the 14N channel is approximately 80 kHz or more, while the PM pulse length lasts 10 rotor periods. For the first time, multiple 1H-14N heteronuclear dipolar couplings, thus multiple quantitative distances, are simultaneously and reliably extracted by fitting the experimental fraction curves with the analytical expression. The size of the 1H-14N dipolar interaction is solely used as a fitting parameter. These determined distances are in excellent agreement with those derived from diffraction techniques.
Related Concept Videos
Distance Measurements by Taping
Electronic Distance Measuring Instruments
Design Example: Measuring Distance Between Two Points with Obstructions
Distance Problem
Short-distance Transport of Resources
Distance Corrections