Patients with high left ventricular filling pressure may be missed applying 2016 echo guidelines: a pilot study

Matthieu Michaud1, Vincent Maurin1, Marc Simon1

  • 1Echocardiography Laboratory, Department of Cardiology and Cardiac Surgery, Clinique Saint Augustin, 114 avenue d'Arès, 33200, Bordeaux, France.

Summary

The 2016 echocardiography guidelines may misdiagnose left ventricular filling pressure (LVFP). Pulmonary venous flow analysis, excluded from current guidelines, is crucial for accurately assessing left ventricular end-diastolic pressure (LVEDP).

Related Concept Videos

Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
836
Echo01:06

Echo

The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
911
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
483
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer02:57

Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer

Gas pressure is caused by force exerted by gas molecules colliding with the surfaces of objects. Although the force of each collision is very small, any surface of an appreciable area experiences a large number of collisions in a short time, which can result in high pressure.
42.7K