Patients with high left ventricular filling pressure may be missed applying 2016 echo guidelines: a pilot study
Matthieu Michaud1, Vincent Maurin1, Marc Simon1
1Echocardiography Laboratory, Department of Cardiology and Cardiac Surgery, Clinique Saint Augustin, 114 avenue d'Arès, 33200, Bordeaux, France.
The 2016 echocardiography guidelines may misdiagnose left ventricular filling pressure (LVFP). Pulmonary venous flow analysis, excluded from current guidelines, is crucial for accurately assessing left ventricular end-diastolic pressure (LVEDP).
Area of Science:
- Cardiology
- Echocardiography
- Cardiovascular Physiology
Background:
- Current 2016 guidelines for echocardiographic evaluation of left ventricular filling pressure (LVFP) utilize a limited algorithm.
- This algorithm primarily focuses on left atrial pressure indicators and excludes pulmonary venous flow analysis, which directly assesses left ventricular end-diastolic pressure (LVEDP).
- The exclusion of pulmonary venous flow may lead to underestimation of elevated LVEDP in certain patient populations.
Purpose of the Study:
- To determine the proportion of patients diagnosed with normal LVFP according to 2016 guidelines who actually have abnormal pulmonary venous flow profiles suggesting high LVEDP.
- To investigate the clinical implications of discrepancies between guideline-based LVFP assessment and pulmonary venous flow analysis.
Main Methods:
- Prospective study of 76 patients with stable ischemic cardiomyopathy and aortic stenosis prior to cardiac surgery.
- Comprehensive echocardiography was performed, including standard LVFP criteria and detailed pulmonary and mitral A wave duration analysis.
- Patients were categorized based on 2016 guideline recommendations for LVFP and pulmonary venous flow patterns (Apd-Amd duration).
Main Results:
- Of 58 patients classified as having normal LVFP by 2016 guidelines, 26 (45%) exhibited abnormal pulmonary venous flow (Apd-Amd duration > 30 ms), indicating high LVEDP.
- These 26 patients had significantly higher left ventricular (LV) mass and shorter mitral A wave durations compared to those with concordant normal LVFP and normal pulmonary venous flow.
- The findings highlight a significant discordance between the current guideline-based LVFP assessment and direct LVEDP evaluation via pulmonary venous flow.
Conclusions:
- The 2016 echocardiographic guidelines for LVFP may misclassify a substantial proportion of patients with elevated LVEDP.
- Pulmonary venous flow analysis, specifically Apd-Amd duration, should be reconsidered for inclusion in LVFP assessment algorithms.
- Incorporating pulmonary venous flow is particularly important in patients with unexplained symptoms, high LV mass, or truncated mitral A waves to ensure accurate LVEDP evaluation.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Pilot and Numeric Relaying
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Guidelines for Nursing Documentation II
Timely documentation is crucial to ensure continuity of care for patients. Any delays in recording or reporting medical information can result in medical errors and even adverse patient outcomes. From medication administration to diagnostic test results, every detail must be accurately and promptly documented to provide the best possible care for patients.
Legal Guidelines for Documentation