Related Experiment Video
Updated: Jan 21, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry for Quantitative Amino Acid Analysis
David M Bunk1, Mark S Lowenthal2
1Biomolecular Measurement Division, National Institute of Standards and Technology (NIST), Gaithersburg, MD, USA. david.bunk@nist.gov.
Abstract:
The role of amino acid analysis in bioanalysis has changed from a qualitative to a quantitative technique. With the discovery of both electrospray ionization and matrix-assisted laser desorption ionization in the early 1990s, the use of amino acid analysis for qualitative analysis of proteins and peptides has been replaced by mass spectrometry. Accurate measurement of the relative molecular masses of proteins and peptides, peptide mapping, and sequencing by tandem mass spectrometry provide significantly better qualitative information than can be achieved from amino acid analysis. At NIST, amino acid analysis is used to assign concentration values to protein and peptide standard reference materials (SRMs) which, subsequently, will be used in the calibration of a wide variety of protein and peptide assays, such as those used in clinical diagnostics. It is critical that the amino acid analysis method used at NIST for assigning concentration values in SRM deliver the highest accuracy and precision possible. Therefore, we have developed an amino acid analysis method that uses isotope dilution LC-MS/MS-the analytical technique routinely used at NIST to certify analyte concentrations in SRMs for a wide variety of analytes. We present here our most recent method for the quantification of amino acids using isotope dilution LC-MS/MS.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Mass Spectrometry: Isotope Effect
Tandem Mass Spectrometry
Amino acids
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...