Related Experiment Video
Updated: Jan 21, 2026

Low-Dose Gamma Radiation Sterilization for Decellularized Tracheal Grafts
Published on: April 14, 2023
A study on the correlation between radiation field size and gamma index passing rate for MatriXX
Kai Xie1,2, Hongfei Sun1,2, Liugang Gao1,2
1Department of Radiation Oncology, Changzhou No. 2 People's Hospital, Nanjing Medical University.
Abstract:
This study aimed to analyze the influence of the radiation field size on the passing rate of the treatment planning system using MatriXX if the field irradiated the circuit.Two sets of static fields which were 10 cm and 30 cm in the left-right direction (X), and was 31 cm to 40 cm in gun-target direction (Y) were designed. In these fields, the gantry was 0 and the monitor units were 200 MU. Two plans from an esophagus carcinoma patient with a planning target volume of 86.4 cm and a cervical carcinoma patient with a planning target volume (PTV) of 2094.1 cm were chosen. The passing rates of these plans were gained without and with protecting the circuit area from lead alloys. The gamma analysis was used and the standard was set to 3%/3 mm.The verification passing rate decreased from 95.0% to 69.2% when X was 10 cm while Y increased from 31 cm to 40 cm. With the protection from low melting point lead alloys, the passing rate was from 96.2% to 89.6%. The results of the second set of plans without lead alloys were similar but the passing rate decreased more sharply. The passing rates of the 2 patients were 99.5% and 57.1%. With the protection of the lead alloys, their passing rates were 99.8% and 72.1%, respectively.The results showed that with the increase of the radiation field size in the Y direction, more areas were irradiated in the circuit, and the passing rate gradually decreases and dropped sharply at a certain threshold. After putting lead alloys above the circuit, the passing rate was much better in the static field but was still less than 90% in the second patient volumetric modulated arc therapy (VMAT) because the circuit was irradiate in other directions. In daily QA, we should pay attention to these patients with long size tumor.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Related Concept Videos
Biological Effects of Radiation
First Pass Effect
Depending on the route of administration, drugs can be metabolized in the liver, intestine, lungs, and vasculature. Orally administered drugs are first absorbed through the...
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Single-pass Transmembrane Proteins
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if: