Estimation of cellular-interstitial water exchange in dynamic contrast enhanced MRI using two flip angles
Jin Zhang1, Sungheon Gene Kim1
1Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University School of Medicine, New York, NY, USA.
Purpose:
To investigate the feasibility of using multiple flip angles in dynamic contrast enhanced (DCE) MRI to reduce the uncertainty in estimation of intracellular water lifetime (τi ).
Methods:
Numerical simulation studies were conducted to assess the uncertainty in estimation of τi using dynamic contrast enhanced MRI with one or two flip angles. In vivo experiments with a murine brain tumor model were conducted at 7T using two flip angles. The in vivo data were used to compare τi estimation using the single-flip-angle (SFA) protocol with that using the double-flip-angle (DFA) protocol. Data analysis was conducted using the two-compartment exchange model combined with the three-site-two-exchange model for water exchange.
Results:
In the numerical simulation studies with a range of contrast kinetic parameters and signal-to-noise ratio = 20, the median bias of τi estimation decreased from 72 ms with SFA to 65 ms with DFA, and the corresponding median inter-quartile range reduced from 523 ms to 156 ms. In the in vivo studies, τi estimation with SFA was not successful in most voxels in the tumors, as the estimated τi values reached the upper limit of the parameter range (2 s). In contrast, the estimated τi values with DFA were mostly between 0.2 and 1.5 s and homogeneously distributed spatially across the tumor. The τi estimation with DFA was less sensitive to arterial input function scaling but more sensitive to pre-contrast T1 than the other contrast kinetic parameters.
Conclusion:
This study results demonstrate the feasibility of using multiple flip angles to encode the post-contrast time-intensity curve with different weighting of water exchange effect to reduce the uncertainty in τi estimation.
More Related Videos
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Social Exchange Theory
Gas Exchange and Transport
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Water and Mineral Acquisition
Capillary Exchange
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...