Physical Activity Measurement in Children Accepting Table Tennis Training
Published on: July 27, 2022
Comparison of a Wearable Tracker with Actigraph for Classifying Physical Activity Intensity and Heart Rate in
Seoungki Kang1, Youngdeok Kim2, Wonwoo Byun3
1Graduate School of Education, Yongin Univerisity, 134 Yongindaehak-ro, cheoin-gu, Yongin-si 449-714, Korea.
Insights
The Fitbit Charge HR (FCH) accurately classifies sedentary behavior in children. It also shows comparable validity to research-grade monitors for moderate to vigorous physical activity (PA), with high reliability across devices.
Area of Science:
- Pediatric physical activity monitoring
- Wearable sensor technology validation
- Biomedical engineering and kinesiology
Background:
- Accurate assessment of physical activity (PA) intensity in children is crucial for understanding health behaviors.
- Consumer-grade wearable devices like the Fitbit Charge HR (FCH) are increasingly popular but require validation against research-grade instruments.
- Existing research often focuses on adult populations, necessitating specific studies in pediatric cohorts.
Purpose of the Study:
- To evaluate the validity and reliability of the Fitbit Charge HR (FCH) for classifying physical activity (PA) intensity in children.
- To compare the performance of the FCH against ActiGraph (AG) accelerometers and indirect calorimetry.
- To assess the FCH's accuracy in distinguishing between sedentary, light, and moderate-to-vigorous PA categories.
Main Methods:
- Forty-three children participated, engaging in 12 different physical activities (PAs) of varying intensities.
- Participants simultaneously wore the FCH, ActiGraph (AG) accelerometers on both wrists, a Polar heart rate monitor, and a portable indirect calorimeter.
- Data from FCH and AG were compared against indirect calorimetry for classifying PA intensity levels and for step measurements.
Main Results:
- The FCH demonstrated the highest classification accuracy for sedentary behavior (81.1%).
- Crouter's algorithm on the non-dominant wrist achieved the highest classification accuracy for light intensity PA (72.4%) and moderate-to-vigorous PA (81.8%).
- The FCH showed comparable validity to AG for moderate-to-vigorous PA (70.8% vs. 81.8%) and high reliability in step measurements (ICC = 0.92–0.94).
Conclusions:
- The Fitbit Charge HR (FCH) offers good validity for assessing sedentary behavior in children.
- FCH demonstrates similar validity to research-grade monitors for classifying moderate-to-vigorous physical activity.
- High agreement and reliability were observed between the FCH and ActiGraph accelerometers across various measurements.
Abstract:
Introduction: To examine the validity and reliability of the Fitbit Charge HR (FCH), wrist-worn ActiGraph (AG) accelerometers were used for assessing the classification of physical activity (PA) into intensity categories in children. Methods: Forty-three children (n = 43) participated in the study. Each participant completed 3 min bouts of 12 PAs ranging from sedentary to vigorous intensity while simultaneously wearing FCH and AG on both hands, a Polar HR monitor, and a portable indirect calorimeter. Total time spent in different PA intensity levels measured by FCH and AG were compared to the indirect calorimetry. Results: The highest classification accuracy values of sedentary behavior was 81.1% for FCH. The highest classification (72.4%) of light intensity PA was observed with Crouter's algorithm from the non-dominant wrist. Crouter's algorithm also show the highest classification (81.8%) for assessing moderate to vigorous intensity PA compared to FCH (70.8%). Across the devices, a high degree of reliability was found in step measurements, ranging from an intra-class correlation (ICC) = 0.92 to an ICC = 0.94. The reliability of the AG and the FCH showed high agreement for each variable. Conclusion: The FCH shows better validity for estimating sedentary behavior and similar validity for assessing moderate to vigorous PA compared to the research-grade monitor. Across the devices, the reliability showed the strongest association.
Related Concept Videos
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
IR Spectrum Peak Intensity: Amount of IR-Active Bonds
Classifying Matter by State
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...