Related Experiment Video
Updated: Jan 21, 2026

Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
PV isolation guided by esophageal visualization with a tailored ablation strategy for the avoidance of esophageal
Yang Ye1, Shi-Quan Chen1, Yi-Fei Lu1,2
1Department of Cardiology, Sir Run Run Shaw Hospital, College of Medicine, Zhejiang University, Hangzhou, 310016, Zhejiang, People's Republic of China.
Purpose:
Radiofrequency ablation along the posterior wall of the left atrium may lead to atrioesophageal fistula due to esophageal thermal injury. The purpose of our study was to prospectively investigate whether ablation guided by soluble contrast esophageal visualization (SCEV) reduces injury during atrial fibrillation (AF) ablation.
Methods:
Seventy-eight patients with paroxysmal AF undergoing circumferential pulmonary vein isolation (PVI) were randomized to a SCEV group (n = 39) and control group without visualization (n = 39). Cine imaging of the esophagus was performed during soluble contrast swallowing at the beginning of ablation, after adjacent ipsilateral PVI and at the end of the procedure. The ablation lesion set was modified to avoid radiofrequency delivery within the contrast esophagram boundaries. In the control group, a single final ingestion was performed at the end of the procedure. Esophageal injury was assessed by esophagogastroscopy within 24 h in all patients.
Results:
In the control group, the ablation lesion crossed over the esophagus in 46.2% of patients, whereas in SCEV group, the ablation line violated the boundaries of the esophagus unavoidably in 15.4% of patients (confidence interval (CI); 1.61-13.98, p = 0.003). The incidence of esophageal injury was significantly lower in patients that underwent ablation with SCEV (5.1% vs. 20.5%, CI; 0.04-1.06, p = 0.042). Regardless of randomization group, patients who received ablation which overlapped the esophagus had a higher incidence of esophageal injury compared with those without overlap (37.5 vs. 1.9%, CI; 3.73-271.37, p = 0.000).
Conclusions:
Esophageal contrast visualization helps to reduce the potential for esophageal injury during paroxysmal AF ablation. This simple procedural adjunct has important implications to improve safety of paroxysmal AF ablation procedures globally.
More Related Videos
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Esophageal Varices-I: Introduction
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...