Chromium and Lead adsorption by avocado seed biomass study through the use of Total Reflection X-Ray Fluorescence
S P Boeykens1, N Redondo1, R Alvarado Obeso1
1Universidad de Buenos Aires, Facultad de Ingeniería, Laboratorio de Química de Sistemas Heterogéneos (LaQuíSiHe), Paseo Colón 850, 5to piso, 1063, Buenos Aires, Argentina.
Abstract:
Adsorption is an effective method for the treatment of wastewater containing low concentrations of heavy metals. This kind of metals such as Chromium and Lead could affect health and the ecosystem. In this work, biomass of avocado seed was used as adsorbent. It was tested as adsorbent in natural form (NB), as a chemically activated (AB) form and as activated carbon (AC). Batch reactors were used to investigate the adsorbent efficiency. Concentration of metal ions was measured using Total Reflection X-Ray Fluorescence. Operational conditions influencing adsorption, such as: pH, adsorbent dose, initial concentration and contact time, were measured and controlled. The 80% of adsorption was reached, at pH: 5 and 25 °C, when were used 50 mL of: a 20 mg L-1 of Cr (VI) solution with a dose of 1.25 g of NB, a 30 mg L-1 of Pb (II) solution with a dose of 0.15 g of NB, a 50 mg L-1 Pb (II) solution with a dose of 0.15 g of AB, a 30 mg L-1 Cr (VI) solution with a dose of 0.35 g of AB, a 30 mg L-1 of both metals, with a dose of 0.15 g of AC for Pb (II) and 0.7 g of AC for Cr (VI). In all cases, the pH value before and during the experiments remained constant, indicating the lack of acid/base reactions during the processes. The Langmuir adsorption isotherm model best fitted to the experimental data. The experimental results from kinetic studies best correlated using the pseudo-second order model. An increase in the remotion of both ions (Pb (II) and Cr (VI)), was observed when comparing the results obtained using the activated biomass. However, considering the loss of biomass that the pre-treatment causes, the remotion per gram of initial biomass does not vary significantly.
More Related Videos
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Analyte Adsorption and Distribution
Seed Structure and Early Development of the Sporophyte


