Improved Enzyme Protection Assay to Study Staphylococcus aureus Internalization and Intracellular Efficacy of Antimicrobial Compounds
Published on: September 8, 2021
Daptomycin-modified magnetic beads integrated with lysostaphin for selective analysis of Staphylococcus
Mengyao Wang1, Enci Fan1, Yue Wu1
1Key Laboratory of Luminescence and Real-Time Analytical Chemistry (Ministry of Education), College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
Abstract:
An antibiotic-affinity method was developed for analyzing Staphylococcus on the basis of the strong binding capability of daptomycin towards Gram-positive bacteria cellular membrane, as well as the selective lytic action of lysostaphin towards Staphylococcus. Daptomycin-modified magnetic beads were adopted to enrich Staphylococcus from sample matrix. Afterwards lysostaphin was adopted to lyse Staphylococcus, which can hydrolyze pentaglycine cross-linkers of peptidoglycan composing the cellular wall of Staphylococcus. The concentration of Staphylococcus was quantified by collecting the bioluminescent signal of the released intracellular adenosine triphosphate of the enriched Staphylococcus. Staphylococcus aureus (S. aureus) was analyzed as a model bacterium to study the feasibility of the proof-of-principle work. For bioluminescent analysis of S. aureus with the developed method, the linear range was 5.0 × 102-5.0 × 106 colony forming units mL-1, and the limit of detection was 3.8 × 102 colony forming units mL-1. The analytical procedure consisting of bacterial enrichment, cell lysis and signal collection can be accomplished within 20 min. Some common Gram-positive bacteria and Gram-negative bacteria all indicated very low interference to the analysis of the target bacterium. It has been successfully used to analyze S. aureus in milk as well as physiological saline injection, indicating its application potential for real samples.
Related Concept Videos
What is Natural Selection?
Antibiotic Selection
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Types of Selection
Frequency-dependent Selection
The Integrated Rate Law: The Dependence of Concentration on Time