Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Mechanical circulatory support in cardiogenic shock from acute myocardial infarction: Impella CP/5.0 versus ECMO
Mina Karami1, Corstiaan A den Uil2,3, Dagmar M Ouweneel1
1Department of Cardiology, Heart Center, Amsterdam UMC, University of Amsterdam, The Netherlands.
Background:
Short-term mechanical circulatory support devices are increasingly used in cardiogenic shock after acute myocardial infarction. As no randomised evidence is available, the choice between high-output Impella or extra-corporeal membrane oxygenation (ECMO) is still a matter of debate. Real-life data are necessary to assess adverse outcomes and to help guide the treatment decision between the different devices. The purpose of this study was to compare characteristics and clinical outcomes of Impella CP/5.0 with ECMO support in patients with cardiogenic shock from myocardial infarction.
Methods:
A retrospective, two-centre study was performed on all cardiogenic shock from myocardial infarction patients with Impella CP/5.0 or ECMO support, from 2006 until 2018. The primary outcome was 30-day mortality. Potential baseline imbalance between the groups was adjusted using inverse probability treatment weighting, and survival analysis was performed with an adjusted log-rank test. Secondarily, the occurrence of device-related complications (limb ischaemia, access site-related bleeding, access site-related infection) was evaluated.
Results:
A total of 128 patients were included (Impella, N=90; ECMO, N=38). The 30-day mortality was similar for both groups (53% vs. 49%, P=0.30), also after adjustment for potential baseline imbalance between the groups (weighted log-rank P=0.16). Patients with Impella support had significantly fewer device-related complications than patients treated with ECMO (respectively, 17% vs. 40%, P<0.01).
Conclusions:
Patients treated with Impella CP/5.0 or ECMO for cardiogenic shock after myocardial infarction did not differ in 30-day mortality. More device-related complications occurred with ECMO compared to Impella support.
Related Concept Videos
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Anatomy of the Circulatory System
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Support Reactions in Three Dimensions
Ball and Socket Joint is one of the supports allowing free rotation about any axis. This freedom of rotation is...