Acellular Dermal Matrix Mistaken as Recurrence of Malignancy Following Surgery on Positron Emission
Seokhwan Lee1, Soo-Keun Kong1, Seong Hwan Bae2
1Department of Otorhinolaryngology and Biomedical Research Institute, Pusan National University School of Medicine, Pusan National University Hospital, Busan, Korea.
Objectives:
To report a rare clinical presentation of an acellular dermal matrix (ADM) used during lateral temporal bone resection mimicking recurrence of cancer of external auditory canal (EAC) on positron emission tomography/computed tomography (PET/CT) 9 months after surgery.
Methods:
Case report and literature review.
Results:
A 71-year-old woman underwent lateral temporal bone resection 9 months earlier for management of squamous cell carcinoma of the EAC. She exhibited recurrence of the tumor on 18F-FDG PET/CT with an intense uptake value (SUVmax 12.8) at the operated site. Exploration was conducted as the location of the lesion was unfavorable to perform biopsy. However, histopathologic evaluation revealed that the lesion was the ADM implanted during surgery.
Conclusions:
Care should be taken when using an ADM during malignant tumor surgery if the site of surgery is not conducive for fine needle aspiration or biopsy.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Emission Spectra