Related Experiment Video
Updated: Jan 21, 2026

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Syndesmotic Fixation Utilizing a Novel Screw: A Retrospective Case Series Reporting Early Clinical and Radiographic
Derek Stenquist1,2,3, Brian T Velasco1,2,3, Patrick K Cronin1,2,3
1Harvard Combinated Orthopaedic Surgery Residency Program, Massachusetts General Hospital, Boston, Massachusetts (DS, PKC).
Abstract:
Background. Syndesmotic disruption occurs in 20% of ankle fractures and requires anatomical reduction and stabilization to maximize outcomes. Although screw breakage is often asymptomatic, the breakage location can be unpredictable and result in painful bony erosion. The purpose of this investigation is to report early clinical and radiographic outcomes of patients who underwent syndesmotic fixation using a novel metal screw designed with a controlled break point. Methods. We performed a retrospective review of all patients who underwent syndesmotic fixation utilizing the R3lease Tissue Stabilization System (Paragon 28, Denver, CO) over a 12-month period. Demographic and screw-specific data were obtained. Postoperative radiographs were reviewed, and radiographic parameters were measured. Screw loosening or breakage was documented. Results. 18 patients (24 screws) met inclusion criteria. The mean follow-up was 11.7 months (range = 6.0-14.7 months). 5/24 screws (21%) fractured at the break point. No screw fractured at another location, nor did any fracture prior to resumption of weight bearing; 19 screws did not fracture, with 8/19 intact screws (42.1%) demonstrating loosening. There was no evidence of syndesmotic diastasis or mortise malalignment on final follow-up. No screws required removal during the study period. Conclusion. This study provides the first clinical data on a novel screw introduced specifically for syndesmotic fixation. At short-term follow up, there were no complications and the R3lease screw provided adequate fixation to allow healing and prevent diastasis. Although initial results are favorable, longer-term follow-up with data on cost comparisons and rates of hardware removal are needed to determine cost-effectiveness relative to similar implants.Level of Evidence: Level IV: Retrospective case series.
More Related Videos
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Resistors In Series
In a series circuit, the...
Predicting Reaction Outcomes
Series Resonance

