Related Experiment Video
Updated: Jan 21, 2026

Ex Vivo Infection of Murine Epidermis with Herpes Simplex Virus Type 1
Published on: August 24, 2015
Use of a corneal impression membrane and PCR for the detection of herpes simplex virus type-1
Matthias Brunner1, Tobi Somerville2,1, Caroline E Corless3
1Department of Corneal and External Eye Diseases, Royal Liverpool University, Hospital, Liverpool, UK.
Abstract:
Purpose. To investigate the use of a corneal impression membrane (CIM) for the detection of herpes simplex virus type 1 (HSV-1) in suspected herpes simplex keratitis (HSK).Methodology. In the laboratory study, swabs and CIMs made from polytetrafluoroethylene were spiked with different concentrations of HSV-1. DNA was extracted and real-time PCR undertaken using two sets of primers. In the clinical study, consecutive patients presenting with suspected HSK were included. For each patient, samples were collected from corneal lesions with a swab and a CIM in random order. Clinical details were collected using a standardized clinical form and patients were categorized into probable, presumed and possible HSK.Results. There was no difference in the performance of both primer sets for all HSV-1 dilutions (P=0.83) using a CIM or between a CIM and a swab (P=0.18). In total, 110 patients were included. Overall, 73 patients (66.4 %) had probable, 20 patients (18.2 %) presumed and 17 patients (15.5 %) possible HSV-1 keratitis. The HSV-1 detection rate was significantly higher using a CIM (40/110, 36.4 %) than a swab (28/110, 25.5 %) (P=0.004). In the probable HSV keratitis group, the detection rate using a CIM was 43.8 % compared to 27.4 % for a swab (P=0.004). The cycle threshold values obtained for the conjunctival swabs were higher than those obtained for the CIMs (P<0.001).Conclusions. In suspected HSK, a CIM is a useful alternative to a swab and more likely to detect the presence of HSV-1.
Insights
A corneal impression membrane (CIM) shows higher detection rates for herpes simplex virus type 1 (HSV-1) in suspected herpes simplex keratitis (HSK) cases compared to traditional swabs. This study suggests CIM is a more effective diagnostic tool for HSK.
Area of Science:
- Ophthalmology
- Virology
- Medical Diagnostics
Background:
- Herpes simplex keratitis (HSK) is a significant cause of corneal blindness worldwide.
- Accurate and timely diagnosis of HSK is crucial for effective treatment and prevention of vision loss.
- Current diagnostic methods, primarily swabs, may have limitations in detecting herpes simplex virus type 1 (HSV-1).
Purpose of the Study:
- To evaluate the efficacy of a novel corneal impression membrane (CIM) for detecting HSV-1 in patients with suspected HSK.
- To compare the diagnostic performance of CIM with conventional corneal swabs for HSV-1 detection.
- To assess the utility of CIM as an alternative diagnostic tool in HSK management.
Main Methods:
- A laboratory study involved spiking polytetrafluoroethylene CIMs and swabs with various concentrations of HSV-1, followed by DNA extraction and real-time PCR.
- A clinical study enrolled patients with suspected HSK, collecting samples via both CIM and swab from corneal lesions.
- Patients were categorized into probable, presumed, and possible HSK based on clinical data.
Main Results:
- In laboratory tests, no significant difference was found in primer set performance or between CIM and swab for HSV-1 detection across dilutions.
- In clinical evaluation of 110 patients, CIM demonstrated a significantly higher HSV-1 detection rate (36.4%) compared to swabs (25.5%) (P=0.004).
- The detection rate for probable HSK was notably higher with CIM (43.8%) versus swabs (27.4%) (P=0.004), with lower cycle threshold values for CIM samples.
Conclusions:
- The corneal impression membrane (CIM) is a viable and effective alternative to traditional swabs for diagnosing HSV-1 in suspected herpes simplex keratitis.
- CIM offers improved sensitivity in detecting HSV-1, particularly in cases with probable HSK.
- This enhanced detection capability of CIM can potentially lead to earlier and more accurate diagnosis and treatment of HSK.
Related Concept Videos
Types of Membrane Protrusions
The microvilli, an example of stable protrusions, are finger-like projections...
First Impression
Managing Impressions
PCR
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Impression Management Techniques IV: Altercasting

