Related Experiment Video
Updated: Jan 21, 2026

Immunohistochemical Detection of 5-Methylcytosine and 5-Hydroxymethylcytosine in Developing and Postmitotic Mouse Retina
Published on: August 29, 2018
Developing an optimal short-form of the PTSD Checklist for DSM-5 (PCL-5)
Kelly L Zuromski1,2, Berk Ustun3, Irving Hwang2
1Department of Psychology, Harvard University, Cambridge, Massachusetts.
Background:
Although several short-forms of the posttraumatic stress disorder (PTSD) Checklist (PCL) exist, all were developed using heuristic methods. This report presents the results of analyses designed to create an optimal short-form PCL for DSM-5 (PCL-5) using both machine learning and conventional scale development methods.
Methods:
The short-form scales were developed using independent datasets collected by the Army Study to Assess Risk and Resilience among Service members. We began by using a training dataset (n = 8,917) to fit short-form scales with between 1 and 8 items using different statistical methods (exploratory factor analysis, stepwise logistic regression, and a new machine learning method to find an optimal integer-scored short-form scale) to predict dichotomous PTSD diagnoses determined using the full PCL-5. A smaller subset of best short-form scales was then evaluated in an independent validation sample (n = 11,728) to select one optimal short-form scale based on multiple operating characteristics (area under curve [AUC], calibration, sensitivity, specificity, net benefit).
Results:
Inspection of AUCs in the training sample and replication in the validation sample led to a focus on 4-item integer-scored short-form scales selected with stepwise regression. Brier scores in the validation sample showed that a number of these scales had comparable calibration (0.015-0.032) and AUC (0.984-0.994), but that one had consistently highest net benefit across a plausible range of decision thresholds.
Conclusions:
The recommended 4-item integer-scored short-form PCL-5 generates diagnoses that closely parallel those of the full PCL-5, making it well-suited for screening.
Related Concept Videos
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Chemotherapy-Induced Nausea and Vomiting: 5-HT3 Receptor Antagonists
Diagnostic and Statistical Manual of Mental Disorders (DSM)
Optimal Foraging
Optimization Problems
Power System Three-Phase Short Circuits

