Related Experiment Video
Updated: Jan 21, 2026

Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
An aptamer assay for aflatoxin B1 detection using Mg2+ mediated free zone capillary electrophoresis coupled with
Linlin Sun1, Yapiao Li1, Hailin Wang1
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
Abstract:
We described an aptamer based and Mg2+ mediated free zone capillary electrophoresis-laser induced fluorescence (CE-LIF) assay for aflatoxin B1 (AFB1) detection. This CE-LIF assay applied an anti-AFB1 aptamer with a single fluorescein (FAM) label at 5' end and a short complementary DNA (cDNA). In the absence of AFB1, the cDNA hybridized with the aptamer probe and formed a duplex DNA. The use of running buffer containing MgCl2 allowed good isolation of the duplex DNA from the single stranded DNA in CE. We found introducing a biotin label on the cDNA further improved the isolation. When AFB1 existed in sample solution, the aptamer probe bound with AFB1, dissociating from the duplex DNA. Thus, the duplex DNA peak decreased, while the aptamer probe peak increased during CE-LIF analysis. We achieved detection of AFB1 by measuring the aptamer probe peak. The length of cDNA, the ratio of aptamer to cDNA, and the concentration of MgCl2 in sample buffer and separation buffer had great effect on the aptamer based CE-LIF assay. Under optimized conditions, the detection limit of AFB1 was 0.2 nM, and the dynamic range was from 0.2 nM to 500 nM. Limit of quantitation was 0.5 nM. This CE-LIF assay enabled detection of AFB1 spiked in diluted human serum, diluted human urine, and corn flour samples. This assay exhibits potential for wide application as it integrates the rapidity, high sensitivity, low sample consumption of CE-LIF analysis and the strengths of aptamer.
More Related Videos
08:25Using a Fluorescent PCR-capillary Gel Electrophoresis Technique to Genotype CRISPR/Cas9-mediated Knockout Mutants in a High-throughput Format
Published on: April 8, 2017
14:53Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Hybrid Zones
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Transition Zone
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...