Related Experiment Video
Updated: Jan 21, 2026

Studying Surfactant Effects on Hydrate Crystallization at Oil-Water Interfaces Using a Low-Cost Integrated Modular Peltier Device
Published on: March 18, 2020
Measurements of Normal Incidence Reflection Loss as a Function of Temperature at the Water-Castor Oil Interface
Dong-Gyun Han1, Him-Chan Seo1, Sungho Cho2
1Department of Marine Science & Convergence Engineering, Hanyang University ERICA, Ansan 15588, Korea.
Abstract:
Reflection loss at the water-castor oil interface as a function of temperature was measured in a direction normal to the interface using a 200-kHz acoustic signal. The acoustic impedance of water increases with temperature, whereas that of castor oil decreases. The measured reflection losses varied from 30 to 65 dB, and a sharp rising peak in reflection loss was observed at the temperature at which the acoustic impedance of water became equal to that of castor oil. This temperature is called the temperature of intromission in this paper. These measurements were compared with the model predictions based on a Rayleigh-reflection model using the measured sound speeds of both fluids. The sound speeds in water and castor oil as functions of temperature are the input parameters of the Rayleigh-reflection model, and were measured directly using an arrival time difference method in the temperature range of 5 to 30 °C. The comparison results imply that temperature is an important factor affecting the reflection at the interface separating the two fluids.
More Related Videos
08:50Total Internal Reflection Absorption Spectroscopy TIRAS for the Detection of Solvated Electrons at a Plasma-liquid Interface
Published on: January 24, 2018
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Related Concept Videos
Adaptations that Reduce Water Loss
Loss of Tumor Suppressor Gene Functions
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Protein-protein Interfaces