Related Experiment Video
Updated: Jan 21, 2026

Dorsal Column Steerability with Dual Parallel Leads using Dedicated Power Sources: A Computational Model
Published on: February 10, 2011
Assessment of Standards and Codes Dedicated to CFRP Confinement of RC Columns
Stefan Kaeseberg1, Dennis Messerer2, Klaus Holschemacher3
1Leipzig University of Applied Sciences, Structural Concrete Institute (IfB), Karl-Liebknecht-Str. 143, 04277 Leipzig, Germany. stefan.kaeseberg@htwk-leipzig.de.
Abstract:
Reinforced concrete (RC) columns are often placed under confinement to increase their strength and ductility. Carbon fiber reinforced polymer (CFRP) materials have recently been recognized as favorable confinement systems. At present, a number of national standards and codes dedicated to the design of concrete components strengthened with CFRP in general and CFRP confinement in particular are available. These sets of rules provide design equations for confined reinforced concrete columns with circular and rectangular cross sections. Most of the standards and codes exhibit significant differences, including the used predictive models, limitations, observed effects and covered loading conditions. In this paper, five international standards and design guidelines are introduced and discussed. The purpose is to present a constructive and critical assessment of the state-of-the-art design methodologies available for CFRP confined RC columns and to discuss effects not previously considered properly. Therefore, some recent research efforts and findings from the Leipzig University of Applied Sciences are also introduced. The obtained data is used for a comparative study of the guideline predictive equations. Furthermore, it is shown that some new findings concerning the rupture strength and the maximum strength plus accompanying axial strain of a CFRP confined column are suitable to improve the current guidelines.
Related Concept Videos
RC Circuit with Source
Due to the inherent properties of a capacitor, its voltage cannot change instantaneously. This means that immediately after the switch is closed, the capacitor's voltage remains the same as it was just before the switch was closed.
lncRNA - Long Non-coding RNAs
lncRNA - Long Non-coding RNAs
RC Circuit without Source
Applying Kirchhoff's current law at the top node of the circuit and substituting the current values across the components, a first-order differential equation is obtained. By rearranging the terms...
Applications of RC Circuits
RC Circuits: Charging A Capacitor
When the switch is moved to connect the battery, the circuit reduces to a simple...

